Installation
Instructions
Locating the New Water
Heater
You should carefully choose an indoor location for the new water
heater, because the placement
is a very important
consideration
for the safety of the occupants
in the building
and for the most
economical
use of the appliance.
This
water heater
is not for
use in mobile homes or outdoor
installation.
Whether
replacing
an old water
heater
or putting
the water
heater
in a new location,
the following
critical
points
must be
observed.
1. The location
selected sbould
be indoors as close as practical
to the vent ternfination
point,
and as centralized
with the
water piping system as possible. The water heater, as a[l water
heaters, will eventually
leak. Do not install without adequate
drainage
provisions where water flow will cause damage.
2. The vent piping
cannot
exceed a total of 35 feet inchlding
vertical and horizontal
runs and have no more than 3 elbows.
it cannot slope downward
and horizontal
runs require/"
per
foot rise. All horizontal
runs require adequate
support
at 3½
feet intervals.
3. The water heater requires its own (separate) venting system.
It cannot
be connected
to an existing vent pipe or chimney.
It must terminate
horizontally
to the outdoors.
Whenever
possible terminate
the vent on the leaward side of the build-
ing. NOTE: Condensation
may be created, at times, as the
combustion
gases exit the vent cap and discoloration
of
surfaces
in proximity
to the vent cap may occur.
_IWARNING
The power vent water heater requires itsown (separate) venting
system. It cannot be connected to an existingvent pipe or chim-
ney. It must be terminated horizontally to the outdoors. Failureto
properly installthe venting systemcan result in asphyxiation,a fire
or explosion and can causeDEATH, SERIOUS BODILY INJUR_,
OR PROPERTY DAMAGE.
4. The water beater comes equipped with a 5 foot power cord
which
can be used to connect
to a 110/120
volt power
source if(l)
local codes allow, and (2) there is a three prong
receptacle available.
IIWARNING
Do not useanextension cord. If there isnot a suitable recepta. I
tie and/orlocalcodesprohibituseof a powercord,field wiring
must be provded.
ACAUTION
WATER HEATERS EVENTUALLY
LEAK: Installation of the
water heater must be accomplished in such a manner that if
the tank or any connections should leak, the flow of water
will not cause damage to the structure. When such locations
cannot be avoided, a suitable drain pan should be installed
under the water heater. Drain pans are available at your
local Sears store. Such a drain pan must be not greater than
1½ inches deep, have a minimum length and width of at least
2 inches greater than the water heater dimensions and must
be piped to an adequate drain. The pan must not restrict
combustion air flow. Under no circumstances is the manu-
facturer or Sears to be held liable for any water damage in
connection with this water heater.
5. The location selection must provide adequate clearances for
servicing and proper operation of the water heater.
IIWARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
'VAPORS)
ARE LIKELY TO BE PRESENT OR STORED
'GARAGES,
STORAGE,
AND
UTILITY
AREAS,
ETC):
klammable liquids (such as gasoline, solvents, propane (LP) or
butane, etc.), all of which emit flammable vapors, may be
improperly stored or used in suchareas. The gas water heater
pilot light or main burner can ignite such vapors. The resulting
flashbackand fire can cause death or serious bums to anyone m
the area, as well as property damage.
If installation in such areas is your only option, then the installa.
tion must be accomplished in a way that the pilot flame and
main burner flame are elevated from the floor at least 18 inches.
While this may reduce the chancesof flammable vapors from a
floor spill being ignited,gasolineand other flammable substances
shouldnever be stored or used in the same room or area con-
raining a gas water heater or other open flame or spark produc-
ing appliance.
NOTE: Flammable vapors may be drawn by air currents from
other areas of the structure to the appliance.
•_ WARNING
Propell_nts of aerosol sprays and volatile compounds, (clean-
ers, chlorine based chemicals, refrigerants, etc.) in addition to
being highly flammable in many cases,will also change to cor-
rosive hydrochloric acid when exposed to the combustion
products of the water heater. The results can be hazardous,
and also cause product failure.
AWARNING
This water heater must not be installed directly on carpeting.
Carpeting
must be protected
by a metal or wood panel
beneath the appliance extending beyond the full width and
depth of the appliance by at least 3 inches (76.2mm) in any
direction, or if the appliance is installed in an alcove or closet,
the entire floor must be covered by the panel. Failure to heed
this warning may result in a fire hazard.
AWARNING
Minimum
clearances between the water heater and com-
bustible construction
are 0" at the sides and rear, 5" at the
front, and fl" from the vent pipe. Clearance from the top of the
jacket is 14"on most models. Note that a lesserdimension may
be allowed on some models. Refer to the label on the water
heater adjacent to the gas control valve for all clearances.
J2"_
VEN TILATION
AIR
OPENINGS
Figure
I ]
_IIN
I)" MIN
TOP VIEW II" MIN
_
OF CLOSET
10P VIEW
WITHOUT
DOOR
OF CLOSET
_'
MAX.
Wl]H
DOOR
AlE DUCT