Kenmore Power Miser 9 153.335916 Owner's Manual page 16

Power vent gas water heater
Hide thumbs Also See for Power Miser 9 153.335916:
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Venting (cont'd)
AWARNING
of
Be sure vent pipe is properlyconnectedto preventescape
dangerous fluegases whichcouldcause deadlyasphyxiation.
VENTING
SYSTEM
EXAMPLE
INSTALLATIONS
FOR ALL
MODELS
The vent piping cannot under any circumstances be run down-
hill.
AWARNING
Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator
and air
conditioner refrigerants,
swimn_ing pool chemicals, calcium
and sodium chloride, waxes, bleach, and processchemicals are
typical compounds which are potentially corrosive.
3" PVC SCHEDULE
40 VENT
PIPING
Supplied in the carton with the water heater are:
1. A 3" PVC Schedule 4045 ° vent cap with wire screen.
2. A 3" PVC Schedule 40-90 ° street ell; used to connect the
vent pipe to the water heater when the vent pipe is to be
turned horizontally directly off the blower.
3. A 5' section of 3" PVC Schedule 40 pipe (more may be
required and must be supplied locally).
3" PVC SCHEDULE 40
90° ELBOW
VENT CAP
WITH
SCREEN
I
1. The
water
heater
requires
its own
(separate)
venting
system.
2. 3" PVC, ABS or CPVC Schedule 40 piping and fittings are
acceptable materials for the vent system on all 40 gallon
models and 50 gallon 40,000 BTU/HR models.
3. It cannot
be connected
to existing
vent
piping
or
chimney.
4. It must terminate
horizontally
to the outdoors.
The vent piping can be installed as follows:
1. No more than 3 elbows can be used.
4>
MIN. RISE I/4"
PER FOOT
MAX, 3
MAX
20'
MIN. RISE i/4"
PER FOOT
16
TOTAL VERTICAL AND
HORIZONTAL
RUNS
CANNOT
EXCEED 35'
MIN. RISE I/4"
PER FOOT
TOTAL
VERTICAL
AND
HORIZONTAL
RUNS
CANNOT
EXCEED
35'