11.Replace t heaccess p anel.
FIGURE 21,
12. Complete
wiring
to the water
heater,
or if completed,
turn
"ON" electric
power to the water
heater after filling the tank
with water.
FIGURE 22,
improper
installation
and use may result
in property
damage,
• Fill tank with water
before operation.
Never
use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
'ON"
power.
Wiring
Improper
installation
and use may result
in property
damage.
, FiJl tank with water
before operation.
Never
use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
on power.
You must
provide
all wiring
of the proper
size
outside
of the
water
heater. You must obey
!ocal codes
and electric
company
requirements
when
you
install
this wiring.
If you are not familiar
with electric
codes
and practices,
or if you
have any doubt,
even the slightest
doubt,
in your ability to connect
the wiring to this water heater,
obtain the service
of a competent
electrician.
Contact
your
Sears
salesperson
to arrange
for a
professional
electrician.
Fire Hazard I Electric
Shock
Hazard
i
®
Do not use this water
heater
with
any voltage
other than shown
on the
model rating plate.
Failure to use the correct voJtage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage.
14
WATER
HEATERS
EQUIPPED
FOR ONE VOLTAGE
ONLY: This
water
heater
is equipped
for one type voltage
only. Check
the
rating plate near the bottom
access
pane! for the correct
voltage.
DO NOT use this water
heater
with any voltage
other than the
one shown
on the model
rating
plate.
Failure
to use the correct
voltage
can
cause
problems
which
can
result
in
DEATH,
SERIOUS
BODILY
INJURY,
OR PROPERTY
DAMAGE.
If you
have any questions
or doubts
consult
your
electric
company.
If wiring
from your fuse box or circuit
breaker
box was aluminum
for your old water heater,
replace
it with copper
wire. If you wish
to reuse
the existing
aluminum
wire,
have
the connection
at
the water heater
made
by a competent
electrician.
Contact
your
Sears
salesperson
to arrange
for a professional
electrician.
Provide
a way
to easily
shut
off the electric
power
when
working
on the water
heater.
This
could
be with
a circuit
breaker
or fuse
block
in the entrance
box
or a separate
disconnect
switch.
Install
and connect
a circuit
directly
from
the main fuse
or
circuit
breaker
box. This
circuit
must
be the right size
and
have its own fuse or circuit
breaker.
Refer to the chart
in the
"Product
Specifications"
section
for the correct
size wire and
fuse or circuit
breaker.
3. If metal
conduit
is used for the grounding
conductor:
The grounding
electrode
conductor
shall be of copper,
aluminum,
or copperclad
aluminum.
The
material
shall be of one continuous
length
without
a splice
or
joint.
a.
Rigid
metal
conduit,
intermediate
metal
conduit,
or
electrical
metallic tubing
may be used for the grounding
means
if conduit
or tubing
is terminated
in fittings
approved
for grounding.
C.
Flexible
metal
conduit
or flexible
metallic
tubing
shall
be permitted
for
grounding
if all
the
following
conditions
are met: