MICROCOMPUTER'S TERMINAL DESCRIPTION
UPD703033GC050 (IC1: X14)
SYSTEM MICROCOMPUTER
Pin
Name
36
X1
37
Vss
38
Vdd
39
CLKOUT
40
N.C
41
MOTOR
42
MODE3
43
MODE1
44
MODE2
45
N.C
46
SUB1
47
SUB2
48
SUB3
49
CAS/SRM
50
N.C
51
N.C
52
ILL-ON
53
PAN-5V
54
N.C
55
BVdd
56
BVss
57
TYPE1
58
TYPE0
59
N.C
60
N.C
61
ST TYPE1
62
ST TYPE0
63
SRM-SW1
64
PAN-RESET
65
L CE
66
SRM-SW3
67
SRM-SW2
68
FWD/REV
69
MS-CONT
70
AVCONT
71
Avdd
72
Avss
73
Avref
74
PHONE
75
R-REEL
I/O
Purpose
I
Main clock connection terminal.
-
Grounding terminal.
-
Positive power supply terminal.
O
Internal System Clock output.
O
No connection.
Cassette mechanism main motor
O
output terminal.
I
Cassette mechanism mode detection terminal.
I
Cassette mechanism mode detection terminal.
I
Cassette mechanism mode detection terminal.
O
Outputs Low. No connection.
O
Sub-motor output terminal (1).
O
Sub-motor output terminal (2).
O
Sub-motor output terminal (3).
Cassette mechanism/SRM mechanism
O
voltage switching terminal.
O
Outputs Low. No connection.
O
Outputs Low. No connection.
O
FL +B output terminal.
O
Panel 5 V control terminal.
O
Outputs Low. No connection.
-
Positive power supply terminal.
-
Grounding terminal.
I
Destination type switching port.
I
Destination type switching port.
O
Outputs Low. No connection.
O
Outputs Low. No connection.
I
IC2 destination type terminal.
I
IC2 destination type terminal.
I
Panel position detection switch 1.
O
Reset output to Panel u-COM.
I/O CE terminal for LCD driver.
I
Panel position detection switch 3.
I
Panel position detection switch 2.
O
TAPE EQ input switching terminal.
Constant switching terminal in case
I/O
of blank detection.
O
AD reference voltage control output.
-
Positive power supply terminal.
-
Grounding terminal.
Reference voltage supply terminal for
I
A/D converter.
I
PHONE detection terminal.
I
Cassette mechanism reel pulse input (REV).
KRC-709,779R/RY,889
When the motor is running: H.
When it is stopped: L.
Cassette mechanism: H.
SRM mechanism: L.
ON: H, OFF: L
Default: L.
Default: L.
Normal: H. Reset: L. Panel detached: L.
Momentary power down: L.
Microcomputer overrun: L.
FWD: L. REW: H.
During TAPE PLAY: H.
During TAPE FF/REW or other than
TAPE input: L.
Cassette mechanism detected: L.
Cassette mechanism not detected: H.
Same timing as P-ON. H during
operation.
TEL MUTE: No more than 1 V.
NAVI MUTE:2.5 V or more.
Vth = 2.5 V.