Microcomputer's Terminal Description - Kenwood KRC-709 Service Manual

M&t cassette receiver
Hide thumbs Also See for KRC-709:
Table of Contents

Advertisement

KRC-709,779R/RY,889

MICROCOMPUTER'S TERMINAL DESCRIPTION

UPD703033GC050 (IC1: X14)
SYSTEM MICROCOMPUTER
Pin
Name
1
AM+B
2
FM+B
3
AFS
4
PLL-DATA
5
PLL-CLK
6
Evdd
7
GND
8
N.C
9
BEEP
10
REMO
11
P-ON
12
P-STBY
13
IC2-SDA
14
IC2-SCK
15
P-MUTE
16
PRE-MUTE
DIMMER CON
17
18
TEST
19
P-CON
20
ANT-CON
21
MUTE
22
N.C
23
ACC-DET
24
DIMMER
25
SW-5V
26
CH-MUTE
27
CH-CON
28
CH-REQH
29
CH-RST
30
EXT-AMP-CONT
31
RESET
32
XT1
33
XT2
34
REGC
35
X2
4
I/O
Purpose
O
AM power supply terminal.
O
FM power supply terminal.
O
Constant switching when noise is detected.
I/O DATA input/output terminal from/to F/E.
I/O CLOCK input/output terminal from/to F/E.
-
Positive power supply terminal.
-
Grounding terminal.
O
No connection.
O
Beep output terminal.
I
Remote control input terminal.
O
SW 14 V control terminal.
O
Power IC STBY terminal control.
I/O IC2 DATA line.
O
IC2 CLOCK line.
O
Power IC muting terminal.
O
Pre-Out muting terminal.
O
Dimmer control.
-
Test pin.
O
Power control terminal.
O
Antenna control terminal.
O
Muting terminal.
O
No connection.
I
Acc detection terminal.
I
Small detection terminal.
O
5 V power supply terminal.
I
Muting request from CH.
O
CH control output.
O
Request output to CH.
O
Reset output to CH.
O
External amplifier control terminal (In 200 ms).
I
Reset input terminal
I
Sub-clock connection terminal.
-
Sub-clock connection terminal.
Output terminal for the capacitor in the
-
regulator in u-COM.
-
Main clock connection terminal.
Operation Description
During AM operation: H.
During FM operation: H.
Last FM with RDS model: H
During FM seek or AM search: L.
During reception: H.
Power ON: H. Power OFF: L.
Power IC OFF: L. Power IC ON: H.
During reset: Input.
Power OFF: L. All OFF: L.
During TEL muting: L.
During momentary power down: L.
DIMMER: Pulse control.
DIMMER OFF: H.
Power ON: H. Power OFF: L.
TUNER, TI ON: H
ON: Open. OFF: L.
The time constant is 0.48 ms with all
models.
Acc detected: L. Acc not detected: H.
ON: L. OFF: H.
ON: L. OFF: H.
ON: H. OFF: L.
ON: H. OFF: L.
Requested: L.
Normal: L. When the system is
reset,turns H then L in 400 ms after
recovery from reset.
L 40 ms: Bass boost OFF.
L 70 ms: Bass boost LOW.
L 100 ms: Bass boost HIGH.
Normal: H. Reset: L.
The clock count is active even when
Power is OFF.
Power ON: Oscillated.
Power OFF or momentary power
down: Oscillation stopped.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Krc-779rKrc-ryKrc-889Krc-779ry

Table of Contents