Strange Sounds; Operational Conditions; Smelly Water; Air" In Hot Water Faucets - Kenmore 153.330402 Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Troubleshooting
Guide (cont'd)
Operational
Conditions
HOT
COLD
WATERHEATER
(3)
COLDWATER
PRESSURE
INLET FITTING
REDUCING
VALVE WITH
BY-PASS
EXPA( I)SIO N
_'_
TANK
__
PRESSURE G AUGE
INLETCOLD
WATER
SHUTOFF
RECOMMENDED
INSTALLATION
(VERTICAL
MOUNTING)
SMELLY
WATER
in each glasslined
water heater
there
is installed
at least one
anode
rod (see parts
section)
for corrosion
protection
of the
tank. Certain
water conditions
will cause a reaction between this
rod and the water. The most common
complaint
associated with
the anode rod is one of a "rotten egg smell". This odor is derived
from hydrogen
sulfide gas dissolved
in the water. The smell is
the restllt of four factors which must all be present for the odor
to develop:
a. a concentration of sulfate in the supply water.
b. little or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
d. an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
WATER HEATER
COLD WATER
INLET FITTING
FLOOR, CEILING
JOIST, ETC.
Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact Sears Service for further information concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment.
HOT
STRAPPING
(,)
EXPANSION
(3)
PRESSURE
REDUCING INLETCOLD
VALVE WITH
WATER
BY-PASS
SHUTOFF
If the smelly water persists after the anode replacement
and chlo-
rination
treatment, we can only suggest that continuous
chlori-
nation
and filtering conditioning
equipment
he considered
to
eliminate
the water problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
"AIR"
IN HOT
WATER
FAUCETS
PRESSUREGAUGE
ALTERNATE
RECOMMENDED
INSTALLATION
(HORIZONTAL
MOUNTING)
STRANGE
SOUNDS
Possible noises due to expansion
and contraction
of some metal
parts during periods of heat-up
and cool-down
do not represent
harmful or dangerous
conditions.
Condensation causes sizzling and popping with the burner area
during beating and coolln{_ periods and should be considered
normal. See Condensation
section.
AWARNING
HYDROGEN
GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical appliances which are connected to the hot water sys-
tem are used (such as a dishwasher or washing machine). If
hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it is open.