Water Piping System
Water
temperature
over
125°F
(52°C) can cause severe
burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and
the
physically
or mentally
disabled
are at highest riskfor scald injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves
are
available.
Read instruction
manual for safe
temperature setting.
Piping, fittings, and valves should be installed according to the
installation drawing (Figure 9). If the indoor installation area
is subject to freezing temperatures,
the water piping must be
properly insulated.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed on
the supply to the entire house in order to maintain equal hot and
cold water pressures.
IMPORTANT:
Heat must not be applied to the water fittings
on the
heater as they may contain nonmetallic parts. If solder
connections
are used, solder the pipe to the adapter
before attaching the adapter to the hot and cold water
fittings.
Always
use
a
good
grade
of
joint
compound
and
be
certain
that
all
fittings
are
tight.
IMPORTANT:
DO NOT over apply joint compound.
Piping Installation
NOTE: To protect against untimely corrosion of hot and cold
water fittings,
it is strongly
recommended
that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.
1.
Install the water piping and fittings as shown in
Figure 9.
Connect the cold water supply (3/4" NPT) to
the
fitting
marked "Cold". Connect the hot water supply (3/4" NPT)
to the fitting marked "Hot".
2.
The installation of unions in both the hot and cold water
supply lines are recommended for ease of removing
the
water heater for service or replacement.
3.
Some local codes may require, and the manufacturer
of
this water heater recommends,
installing a mixing valve
or an anti-scald device in the domestic hot water line as
shown in Figure 9. These valves reduce the point-of-use
temperature
of the hot water by mixing cold and hot water
and are readily available. Contact a licensed plumber or
the local plumbing authority for more information.
4.
Some local codes
may require,
and the manufacturer
of this water heater recommends,
installing a pressure
reducing valve (PRV) in the cold water inlet line where it
enters the residence as shown in Figure 9.
5.
If installing the water heater in a closed water system,
install an expansion tank in the cold water line as specified
under "Closed System/Thermal
Expansion."
6.
Install a shut off valve in the cold water inlet line. It
should be located close to the water heater and be easily
accessible. Know the location of this valve and how to shut
off the water to the heater.
7.
Install a discharge line from the temperature and pressure
relief valve in the opening marked "T & P RELIEF VALVE".
See Figure 10 and the "Temperature and Pressure Relief
Valve" section.)
i:t
_th_V_
_mPamn 2a_ 2
t2lelPiht: rhd :tretrh. i!"
_
ID Minimum
Heat Trap - The top of the heat trap
must be higher than the storage tank
of the water heater.
/
Massachusetts: Install a vacuum relief in cold
water line per section I9 MGL 142.
H(_
Union
'
Union
_Shut-off
Valve (Hot)
:::::_--€_
Untempered Water Outlet
)utlet
I
Mixing
Valve (Optional)
- Follow
the
I
/Mixing
Valve's Manufacturer's Installation
. L_"
Instructions. (Setto 120° F)
pt:ZZ_Tempered
Water to Fixtures
I/_
ate Drain Lines*
_:_
Cold Water Outlet
/
//I
II
_
In a closed
system,
use a
i¢'./
I
I I
_
/thermal
expansion tank.
:_'
I it L
j_ See " Closed
System/
1
II
_
Thermal Expansion"
"Shut-off
Valve
_
(Cold)
-1_6"
Maximum
Drain
Air Gap
_Vacuum
Relief Valve
E:aE_
Cold Water
,
__r_l_
ntet vatve
__4--
Cold Water
_X
Inlet
Whole House Pressure Reducing
Valve (PRV)
should
be installed
where the water supply enters
the residence.
* If an adequate drain is not available for the condensate drain lines then a condensate pump should be used. DO NOT discharge the condensate drain
lines into the metal drain pan.
FIGURE 9.
10