Start Up Conditions
THERMAL EXPANSION
Property
Damage
Hazard
• Avoid water heater damage.
• Install thermal expansion tank or device if necessary.
• Contact qualified installer or service agency.
As water is heated, it expands (thermal expansion). In a closed
system, the volume of water wilt grow. As the volume of water
grows, there wilt be a corresponding
increase in water pressure
due to thermal
expansion.
Thermal
expansion
can cause
premature
tank failure (leakage).
This type of failure is not
covered under the limited warranty. Thermal expansion can also
cause intermittent temperature-pressure
relief valve operation:
water discharged from the valve due to excessive pressure build
up. The temperature-pressure
relief valve is not intended for the
constant relief of thermal expansion. This condition is not covered
under the limited warranty.
A properly-sized
thermal expansion
tank should be installed
on all closed systems to control the harmful effects of thermal
expansion. Thermal expansion tanks are available from Sears
stores and through the Sears Service Centers. Contact the local
plumbing
inspector, water supplier and/or the Sears Service
Center for assistance in controlling these situations.
Table 3: Thermal Expansion Tank Specifications
Model
Tank
Number
Capacity
In Gallons
2
5
153.331020
153.331050
Dimensions
in Inches
Diameter
Length
8 (203 mm)
12-3/4" (323 mm)
11 (279 mrn)
14-3/4" (375 mm)
Pipe
Fitting
On Tank
3/4"Male
3/4"Male
Table 4: Expansion
Tank Sizing
Chart
Inlet*
Water Heater Capacity
Water
(Gallon)
Pressure
30
40
50
66
82
Expansion
Tank
Capacity
Needed
40psi
50psi
60psi
70psi
80psi
2
2
2
5
5
2
2
2
5
5
2
2
5
5
5
2
2
5
5
5
2
5
5
5
5
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE: Expansion
tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion
tank's air pressure must be adjusted to match
that pressure, but must not be higher than 80 psi.
HOT
COLD
COLD WATER
PRESSURE
INLET FITTING
REDUCING
VALVE WITH
BYPASS
61NCH
INLET
COLD
WATER
SHUTOFF
RECOMMENDED
INSTALLATION
(VERTICAL
MOUNTING)
WATER HEATER
FLOOR, CEILING
COLD WATER
JOIST, ETC_
INLET FITFING
HOT
COLD
STRAPPING
PRESSURE
REDUCING
INLET COLD
VALVE WITH
WATER
BY=PASS
SHUTOFF
6INCH
PRESSURE
GAUGE
ALTERNATE
RECOMMENDED
INSTALLATION
(HORIZONTAL
MOUNTING)
FIGURE 22.
STRANGE SOUNDS
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
Operational
Conditions
POWERED ANODE ROD OPERATION
To shelter the glass-lined water tank from corrosion through
electrolysis, this water heater is equipped with a non-sacrificial
powered anode which should not need to be replaced under
normal operating conditions. NOTE: The powered anode oper-
ates only when electrical power is applied.
If the powered anode malfunctions it should be replaced by a
qualified technician.
IMPORTANT:
If a faulty powered anode is not repaired or has
been removed permanently, then all warranties are void.
21