installation
Water
Piping
instructions
(cont'd)
AWARNING
HOTTER
WATER
CAN
SCALD:
Water
heaters
are
intended to produce hot water. Water
heated to a tem-
)erature which will satisfy space heating, clothes washing,
dish washing, and other sanitizing
needs can scald and
)ermanently
injure you upon contact_ Some people are
more likely to be permanently
injured by hot water than
others. These include the elderly, children, the infirm, or
physically/mentally
handicapped.
If anyone using hot
water in your
home fits into one of these groups or if
there is a local code or state law requiring a certain tem-
)erature water at the hot water tap_ then you must tal(e
special precautions.
In addition to using the lowest possi-
ble temperature
setting that satisfies your
hot water
needs, a means such as a mixing valve, shall be used at
the hot water taps used by these people or at the water
heater. Mixing valves are available at plumbing supply or
hardware
stores. Follow manufacturers
instructions
for
installation of the valves_ Before changing the factory set-
ting
on the
thermostat,
read
the
"Temperature
Regulation" section in this manual.
The illustration
shows the attachment
of the water piping to the
water
heater.
The
water
heater
is equipped
with
¾" water
conNectlons_
If a water heater is installed in a closed water supply system;
such as one having a back-flow preventer, check valve, water
meter with a check valve, etc, in the cold water supply; means
shall be provided to control thermal expansion, Contact the
local utility or local Sears Service Center on how to control this
situation,
NOTE:
If using copper
tubing,
solder
tubing
to an adapter
before attaching
the adapter to the cold water inlet connec-
tion. Do not solder the cold water supply line directly to the
cold water inlet. It will harm the dip tube and damage the
taul_
• Look at the top cover of the water heater. The water oudet is
marked hot Put two or three turns of teflon tape around the
threaded end of the threaded-to-sweat
coupling and around
both ends of the ¾" threaded nipple. Using flexible connec-
tors, connect the hot water pipe to the hot water outlet of the
water heater
• Look at the top cover of the water heater The cold water inlet
is marked cold. Put two or three turns of teflon tape around
the threaded
end of the threaded-to-sweat
coupling
and
around both ends of the ¾" threaded nipple, Using flexible
connectors,
connect the cold water pipe to the cold water
inlet of the water heater.
Installation
completed
using Sears
Installation
Kit
FLEXIBLE
WATER
CONNECTORS
.OTOUTLET
TO HOUSHEREAD_D TO
SWEAT COUPLING
_
SHUT-OFF
VALVE
COLD INLET
WATER LINE
THREADED TO
SWEAT COUPLING
314" THREADED
NIPPLE
"<---'--3/4"THREADED
NIPPLE
TEMPERATURE.
PRESSURE
RELIEF VALVE
)ISCHARGE
PIPE
(Do not cap or plug)
6" AIR GAP
FLOOR
DRAIN
NOTE: Your water heater is super insulated to minimize
heat loss from the tanl¢_ Further reduction in heat loss can be
accomplished
by insulating
the hot water lines from the
water heater.