Lexmark X215 MFP Service Manual page 63

Hide thumbs Also See for X215 MFP:
Table of Contents

Advertisement

Main drive motor
FRU
Main drive motor,
system board,
LVPS/HVPS
Document cover open switch
FRU
Document cover
switch,
operator panel
Action
• Perform the
"Motor, Fan,
Solenoid test" on page 3-11
see if the main drive motor turns
on.
• If the motor works but is noisy,
replace the main drive assembly.
• If the motor works correctly in this
test but not during normal printing,
the problem may be associated
with a faulty system board.
• If the motor does not work at all
during this test, make sure the
motor cable is properly
connected.
• If connections are correct and the
problem persists, replace the
main drive assembly.
• If the problem persists, replace
the LVPS/HVPS.
Action
• First, make sure the document
cover open switch cable is
properly seated in CN1 on the
operator panel.
• Disconnect the cable from CN1 on
the operator panel and check
CN1—1 for +5 V dc.
• If the voltage is present, the
document cover switch is faulty.
• If the voltage is not present,
replace the operator panel.
to
Diagnostic information
4038-001
2-31