  • Page 1 Dehumidification System CLI-DH12 | Installation & Operating Instructions...
  • Page 2 Congratulations on your purchase of a Cli~Mate Air Dehumidification System. This air dehumidifier is compact and stylish in design, quiet, portable and easy to operate. Unit effectively removes moisture from the air creating a drier, healthier room environment. Note: Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference.
  • Page 3: Product Specifications

    To achieve best performance; make sure all doors and windows System Specifications CLI-DH12 are closed before turning on the unit. Air Dehumidification System The appliance air vents and air grilles must not be obstructed at...
  • Page 4 OPERATION CONDITIONS AND SAFETY PRECAUTIONS • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in Read all instructions carefully. order to avoid a hazard. • All components need to be installed in accordance with the user • The use of accessory attachments not recommended by the manual instructions for correct performance of unit. appliance manufacturer may result in fire, electric shock or • This appliance is not intended for use by persons (including personal injury.
  • Page 5 • If unit ever tips or falls over when water reservoir is full, immediately unplug the power cord. Ensure unit is dried thoroughly before operation of the unit. • Do not put fingers or other objects in any openings of the unit. During the set up of this product if you have any questions/ comments/ issues DO NOT RETURN TO STORE FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE CALL 1300 764 325 INSTALLATION AND OPERATING INSTRUCTIONS 3...
  • Page 6: Parts Identification Diagram

    A. PARTS IDENTIFICATION DIAGRAM A. Dry Air Outlet B. Control Panel C. Handle D. Humid Air inlet E. Air Filter F. Continuous Drainage Hose* G. Continuous Drainage Outlet (For hose connection) H. Water Reservoir * Continuous drainage hose is an extra drainage option; hose does not need to be connected if using the water reservoir to catch condensed water.
  • Page 7 B. CONTROL PANEL & KEY PADS C. OPERATION INSTRUCTIONS 1. Plug unit into power socket, unit will beep twice and LED monitor lights will illuminate for one second. 2. Press POWER button to turn unit on. Note: The dehumidification setting is automatically set at CON (continuous dehumidification) and default dehumidification speed is set at High (H).
  • Page 8 Note: When the ambient relative humidity is 1% lower than the Note: When the ambient relative humidity is less than or equal to selected relative humidity ratio percentage (RH %), the unit 24°C, the relative humidity ratio setting is 80%.When the ambient compressor will switch off and unit will operate at a Low (L) relative humidity is less than or equal to 24°C - 25 °C, the relative speed level.
  • Page 9: Product Safety Features

    D. PRODUCT SAFETY FEATURES 3. Failure of Humidity & Temperature Sensor When the connection wire between the humidity and temperature 1. Automatic Defrosting sensor is disconnected, the humidity CON light will blink and To ensure the unit operates and performs as stated, the unit has switch unit into continuous dehumidifying mode.
  • Page 10: Maintenance And Repair

    E. OPTIONAL CONTINUOUS DRAINAGE INSTALLATION F. MAINTENANCE AND REPAIR 1. Ensure that unit is OFF and unplugged from wall socket. Before carrying out any maintenance or cleaning of the unit, make sure that the power to the unit is turned off and power cord is 2.
  • Page 11 G. UNIT NOT USED FOR PROLONGED PERIODS If not using the unit for a prolonged period, switch off and unplug the unit, empty the water reservoir, and allow minimum of two days for unit to dry before packing away. Keep unit in a dry and ventilated place.
  • Page 12: Troubleshooting

    H. TROUBLE SHOOTING BEFORE YOU CALL FOR SERVICE PLEASE REVIEW THE TROUBLE SHOOTING TIPS FIRST. Problem Possible Causes What To Do 1. Check connection to wall socket 1. Unit is not plugged into wall socket 2. Check indicator lights to determine which safety feature has No Power 2.
  • Page 13 Problem Possible Causes What To Do 1. Unit not on a level flat surface 1. Reposition or relocate unit onto a flat surface. Loud Noise 2. Faulty internals 2. Call customer care. 1. Water reservoir not installed correctly 1. Reinstall water reservoir 2.
  • Page 14 Your Aquaport 12 Month Repair or Replacement Warranty Conditions Of This Warranty: A quaport warrants this appliance to the first purchaser and subject to 1. This product has been fully installed in accordance with the the stated conditions: user manual installation instructions. Warranty covers any defects in material or workmanship in the 2.
  • Page 16 CUSTOMER HOTLINE: 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone: 1300 764 325 Facsimile: 08 8354 0722 Email: aquaport@aquaport.com.au Web: www.aquaport.com.au...