Bit
6
5:4
3:0
!
WARNING:
camera calibration information, requiring the camera to be returned for recalibration.
WARNING:
minimum of 1 second after power up.
The following table lists all valid commands available to the user. Any commands not
listed should be considered invalid to the 1M30P user.

3.2 ADC Commands

Table 10: Summary of ADC Commands
Control
ADC Board
Soft Reset
User Offset
User Gain
DALSA
Function
Command Type
0 = Write
1 = Read
Always 00
Command Register Address (Reference
Table 10)
Any commands not listed should be considered invalid. Writing to invalid addresses may overwrite
Due to initialization sequencing after power-up, no commands should be sent to the camera for a
Write Command
Hex
Binary
00h
0000 0000
02h
0000 0010
03h
0000 0011
05h
0000 0101
06h
0000 0110
Read Command
Hex
Binary
NA
NA
42h
0100 0010
43h
0100 0011
45h
0100 0101
46h
0100 0110
Function
Resets ADC board only
LS byte of 16 bit user
controllable offset
MS byte of 16 bit user
controllable offset
LS byte of user
controllable gain
MS byte of user
controllable gain
03-32-10001-02