Table of Contents

Advertisement

I
ADJUSTMENT
CAUTION
:DURING
Alignment,
OPEN ''AN7PA~ERN
MARKED WlTH''SHOR7SlLK
JUST LIKE MENTIONED
AT PAGE "PARTS LOCATION",
IF RUBBER ANTIS CONNECTED.
1.ALIGNMENT
FOR REMOTE UNIT
1-1. Tx/Rx VCO & Tx Freq.
Test
Equipment
. Digital Voltmeter
" DC Power Supply
(DC 3.8 V)
" Frequency Counter
Unit Condition
a) Disconnect
Ni-Cd battery which feeds 3.8 V from power supply terminal.
b) Set unit to "TEST" mode by shorting test point TPOO1 and TPO02 together.
c) Feed 3.8V Ni-Cd battery to power supply terminal.
d) Connect frequency counter to ANT test pin. Confirm the current channel is at 10ch.
e) Connect digital voltmeter to Tx/Rx VCO terminal points.
f) Align T253 (Tx) to obtain 2.2~0.l
V DC reading from digital voltmeter respectively.
[
g) AlignT153
(Rx) to obtain 1.5t0.l
V DC reading from digital voltmeter respectively.
h) Tx FREQUENCY
.." Confirm the Tx Freq is 40.000 MHz*l
.2KHz (1 Och) from Freq. counter.
Adjustment
Unit
TX
IC351
6 PIN
Tx VCO
0?
Digital
Frequency
Ant.(H)
Counter
Ant.(E)
39 PIN Rx VCO r
'x
o
Voltmeter
TEsT(TPoo1&TPoo2)
Gnd
I
I
I
I
STEP
I
CONDITION
I CH I
ADJUST
I
ADJUSTED
VALUE
I
SPECIFICATION
[
1.Tx VCO
Tx VCO side
10
T253
2.20V
2.20V *
O.lv
2. Rx VCO
Rx VCO side
10
T153
1
.50V
1.50V k O.lv
3. Tx Frea.
10
-
40.000MHZ
*
1.2 KHZ