CLEARANCE TO COMBUSTIBLES

Back..................2"/50.8mm
Sides.................6"/156.4mm
Floor.................0"/0mm
Top...................24"/610mm
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60Hz circuit with a properly grounded
outlet is required. Preferably, the heater will be on a
dedicated circuit. Other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blow
when the heater is on operation. The unit comes standard
with a 6' (1828mm) long three wire cord exiting from the
rear of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extended cord must be used, it
must be a minimum 16 AWG three wire with grounding
type plug connector and rated no less than 1900 Watts.
WARNING:
before
maintenance
reduce the risk of fire, electrical
shock or personal injury

REPLACING LIGHT BULBS

This fireplace uses two clear 120 Volt, 60 Watt, E-12
socket base light bulbs (small base, chandelier candle
type).The 60 Watt bulbs are located under the log
set/ember bed. For convenience, if one of the bulbs
burns out, it may be a good idea to replace both of the
light bulbs.
1. Turn off power to the unit by unplugging the power
cord.
2. Let fireplace cool if it has been operating.
3.
Open the front door by pulling the handle.
4.
Remove the two screws that secure the log set in
position.
Disconnect
power
attempting
any
or
cleaning
to
WARNING: Electrical outlet wiring
must comply with local building
codes and all other applicable
regulations to reduce the risk of
fire, electrical shock and injury.
WARNING:
fireplace if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and replace
any part of the electrical system if
necessary.

ELECTRICAL SPECIFICATIONS

Voltage..................120 VAC/60Hz
Total Amps..............11.3 Amps
Total Watts..............1345 Watts
Heater Ratings.........1200 Watts
5. Remove the two screws of the front baffle and
take them out.
6.
Examine the bulbs to determine which one
needs to be replaced.
7. While holding the socket, unscrew the defective
bulb(s).
8. Install the new light bulb(s) by holding the socket
and screwing them in.
9. Reinstall the baffle、log set and screen. Follow
the above procedure in reverse order.
WARNING: Do not exceed 60
Watts per bulb. Use of higher
rated bulbs may result in a fire
causing property damage and
personal injury.
Do
not
use
this
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

V50hyld

Table of Contents