Electrical
120VAC / 60 Hz / 1-Ph / 1A
In locations used for storage of combustible materials, signs must be posted to specify
the maximum permissible stacking height to maintain the required clearances from the
heaters to combustibles. Signs must either be posted adjacent to the heater thermostats
or in the absence of such thermostats in a conspicuous location.
Starting current 3 Amp. Running current 1 Amp.
Ignition System:
120 Volt / Hot surface igniter
For thermostat control:
All heaters are designed for compatibility with either 120 Volt thermostat
controllers or 24 Volt thermostat controllers. For use with 120 Volt controllers, the
heater must be plugged into a "switched" 120 Volt duplex receptacle, where the
receptacle is switched by the thermostat controller. Heating zones may be established
where one 120 Volt thermostat, controls more than one heater, provided the total heater
electrical load does not exceed the maximum allowable amperage on the circuit.
For 24 volt thermostat control plug the heater into a 120 Volt duplex receptacle.
Remove the jumper wire on the control box marked "24 Volt thermostat" and connect
the thermostat wire to the terminals. Ensure that if the thermostat has a heat
anticipator, that the heat anticipator is set at maximum. When using a 24 Volt
thermostat, only one heater may be controlled by one thermostat.
Heaters must be electrically grounded in accordance with the National
Electrical Code, ANSI\NFPA 70 or the current Canadian Electrical Code,
CSA C22.1
Polarity of Line voltage and neutral wires must be
.
maintained. The total load of all heaters in a circuit must be considered
for overload control of that circuit. See electrical specifications above.
WARNING

ELECTRICAL SPECIFICATIONS

Gas Supply (inches W.C.) Natural
Manifold pressure
Minimum inlet pressure
Maximum inlet pressure
Gas connection
Vent Connection
Propane
3.5"
10.0"
7.0"
14.0"
14.0"
14.0"
½" N.P.T.
4" O.D.