Kenmore 795.7202 Series Use And Care Manual page 38

Bottom freezer refrigerator
Hide thumbs Also See for 795.7202 Series:
Table of Contents

Advertisement

COOLING/ICE
& WATER
Food is freezing
Food with high water content was
in the refrigerator
placed
near an air vent.
compartment.
Refrigerator
temperature
control is set
incorrectly.
Refrigerator
is installed
in a cold
location.
Frost or ice crystals
form
on frozen
food
(outside
of package).
Door is opened frequently
or for long
periods of time.
Rearrange
items with high water content away from
air vents.
if the temperature
is too cold, adjust the control one
increment
at a time and wait for the temperature
to
stabilize.
Refer to the Setting the Controls section for
more information.
When the refrigerator
is operated
in temperature
below 41°F (5°C), food can freeze in the refrigerator
compartment.
The refrigerator
should not be operated
in temperature
below 55°F (13°C).
When the doors are opened often or for tong periods
of time, warm, humid air enters the compartment.
This
raises the temperature
and moisture level within the
compartment,
increased moisture will lead to frost
and condensation.
To lessen the effect, reduce the
frequency
and duration
of door openings.
Refer to the Doors will not close correctly
or pop
open section in the Troubleshooting
section.
if the temperature
is too cold, adjust the control one
increment
at a time and wait for the temperature
to
stabilize.
Refer to the Setting the Controls section for
more information.
Door is not closing properly.
Refrigerator
or
incorrect
temperature
control settings.
Freezer section is too
cold.
Frost or ice crystals
Condensation
from food with a high
This is normal for food items with a high water
on frozen food
water content
has frozen inside of the
content.
(inside of sealed
food package.
package).
L
Food has been left in the freezer for
a long period of time.
Icemaker is not
Demand exceeds ice storage
making enough ice.
capacity.
House water supply is not connected,
valve is not turned on fully, or valve is
clogged.
Water
filter has been exhausted.
Low house water supply pressure.
Reverse Osmosis filtration
system is
used.
Tubing connecting
refrigerator
to
house supply valve is kinked.
Do not store food items with high water content in the
freezer for a long period of time.
The icemaker will produce
approximately
100 cubes in
a 24 hour period.
Connect the refrigerator
to a cold water supply with
adequate
pressure and turn the water shutoff valve
fully open.
if the problem
persists, it may be necessary to contact
a plumber.
it is recommended
that you replace the water filter:
Approximately
every six months.
When the water filter indicator
turns on.
When the water dispenser output decreases.
When the ice cubes are smaller than normal.
The water pressure must be between 20 and 125 psi on
models without
a water filter and between 40 and 125
psi on models with a water filter.
if the problem
persists, it may be necessary to contact
a plumber.
Reverse osmosis filtration
systems can reduce the
water pressure below the minimum amount and resutt
in icemaker
issues. (Refer to Water
Pressure section.)
The tubing can kink when the refrigerator
is moved
during installation
or cleaning resulting in reduced
water flow. Straighten
or repair the water supply line
and arrange
it to prevent future kinks.