INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
Caution:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an
explosion.
• Where there is much machine oil.
• Salty place such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
Warning:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
Warning:
The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to the unit
falling, water leakage, etc. may result.
Caution:
• Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone.
If the earthing is incorrect, it may cause an electric shock.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place,
etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Inspection and maintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increasing of operating
sound.
• If abnormal sound is heard during operation, consult your dealer.
12
Keep the outdoor unit 3 m or
more away from the antennas
of TV sets or radios.
Inverter type fluo-
rescent lamp
Wall, etc.
To prevent the effect of
a fluorescent lamp, keep
Well-
it away as far apart as
ventilated
possible.
Keep a space to
dry place
prevent the pic-
ture distortion or
100mm or
the noise.
more
500mm or
more
TV
Radio
3 m
1m or more
or more
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work
are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury from the unit falling, water leakage, etc. Consult
your dealer.
Disposal
• To dispose of this product, consult your dealer.
If you have any questions, consult your dealer.

SPECIFICATIONS

Model
Function
Power supply
Standard
SSA 385/386
kW
Capacity
kcal/h
Running current
A
Input
W
Refrigerant filling capacity (R-22)
kg
Note:
Rating condition
SSA 385/386
Cooling — Indoor:
29°C DB, 19°C WB
Outdoor: 46°C DB, 24°C WB
JIS C 9612
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB, (24°C WB)
MCF-18TN
MCF-24TN
Cooling
1ø, 220V, 60Hz
JIS C 9612
SSA 385/386
JIS C 9612
4.4
5.1
5.5
6.3
3780
4720
11.2
9.6
16.3
13.4
2300
1910
3400
2800
1.50
2.15

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Mr.slim mcf-24tn

Table of Contents