Private Communication Systems Mobile Phones 2 Technical Data Length 159 mm Width 55 mm Thickness 16/22 mm Volume 155 cm³ Weight 165 g Performance: GSM class 4 (2 Watt) PCN class 1 (1 Watt) Powersupply: Lithium Ion battery (3,6V/1000mAh) Standby time: up to 30 hours Talk time: Up to 4 hours.
Private Communication Systems Mobile Phones 3 General Information The S6 is the first model of a whole new handset generation in 3 Volt technology. It comes either as a GSM or a PCN version. 4 Mechanical Concept Note: All part numbers refer to mechanical drawing in section 4.1! The S6 consists of two boards, the RF &...
Private Communication Systems Mobile Phones 4.1 S6 GSM / PCN mechanical drawings Figure 1: Mechanical Drawing S6 V1.3 PN MP ST D. Schnoor 10/97...
Page 6
Private Communication Systems Mobile Phones Figure 2: Display with Dust Protection Frame Note: The numbers displayed in the above drawings are NO ORDERING Nos, use the numbers in chapter 11 for ordering! Ordering number for dust protection frame: L36859-A4-C141 Figure 3: Dust Protection Frame V1.3 PN MP ST D.
Private Communication Systems Mobile Phones 4.2 Disassembling the S6 ESD regulations have to be followed! 1. Remove battery and SIM-Card. 2. Unscrew antenna (1130). 3. Unscrew 2 oval head screws (1150) (Torx 1,8x12). 4. Turn out 2 short flat head screws (1140) (Torx 1,8x8). 5.
Private Communication Systems Mobile Phones 1. Put earphone capsule (1120) and microphone (1110) into upper case shell. 2. Insert keypad (1030) into upper case shell (1040). 3. Put dust protection frame (1210) on display window inside upper case shell. 4. If necessary: Insert battery connector into lower case shell (1050). 5.
Page 9
(see table below!) If a bolted handset comes back for service and one of the boards is defective, do not try to separate them. Just send the whole sandwich back to Germany. S6 GSM/PCN Board Versions GSM: PCN: Old version (with bolt):...
4.6 Handset Datecodes Siemens is using the industrial standard DIN EN 60062 to indicate the production / service dates. The code is printed on the IMEI sticker located under the simcard reader. V1.3 PN MP ST D.
Private Communication Systems Mobile Phones -> YY = Datecode The first character of the datecode indicates the year of production: F = 1995 H = 1996 J = 1997 The second character indicates the month of production: 1-9 = january to september O = october N = november D= december...
Private Communication Systems Mobile Phones 5.2 Hardware Description The handset consists of five major integrated circuits: 1) GOLD- C (PMB 2706) This microprocessor is responsible for controlling the keyboard, SIM-Card, EEPROM, Flash and RAM. Furthermore it interfaces the GOLD-SP (PMB 2707), controls the power up/power down of the RF module and sets the amplification of the PA.
Regulator Control RF Supply +6.5 V Linear +2.8 V Power Regulator Control Logic Supply Ignition S6 GSM/PCN SIM Supply Watchdog Power Supply ASIC ON_OFF Button RESET Power Detection Charging On (to P) (from P) From the 3.6 V battery voltage, all other supply voltages of the S6 are derived, controlled by the power supply ASIC.
Private Communication Systems Mobile Phones Furthermore the ASIC generates the supply voltage for the SIM-Card and the RESET signal for the logic devices. The ASIC also checks the presence of the watchdog signal from the P and provides the switching on functionality (ON_OFF button or Ignition signal). During testing ist is advisable to use a battery dummy, connected to a power supply delivering +4V, max 3A.
Private Communication Systems Mobile Phones 6 S6 GSM / PCN Software Options The following list will help you to understand what the different software options are for and how they are used. Keep in mind that many of these features are network dependent, a malfunction cannot automatically be blamed on the handset.
Page 17
Private Communication Systems Mobile Phones If you are using a phase 1 SIM-Card you will see the following: Allow only Set / Clear PHONECODE This will limit all outgoing calls to the numbers stored in the normal Phonebook. Allow last 1-5 Set / Clear PHONECODE This will limit all outgoing calls to the numbers...
Page 18
Private Communication Systems Mobile Phones 3.8.4 All Calls In Set / Clear PASSWORD No incoming calls possible 3.8.5 When Roaming Set / Clear PASSWORD No incoming or outgoing calls when roaming MESSAGES Voice Message Alter / Hear You can save the telephone number of your voice mailbox to hear your messages ..Text ( x old ) Read your received SMS messages...
Page 19
Private Communication Systems Mobile Phones TIME CHARGE Last Call Length and cost of last call Total Calls Clear (PHONECODE) Lenght and cost of all calls Auto Display On / Off Automatic lenght and cost display 1 Minute Beep On / Off 1 minute indication during call Charge Rate Setting of charge rate...
Phone Status This shows your IMEI-Number and the Software-Date (Press left softkey once!) 7 Software programming The software of the S6 GSM / PCN handsets is programmed directly from a PC using the bootadapter (see drawing below). V1.3 PN MP ST D.
Private Communication Systems Mobile Phones Bootadapter RS-232 Connection Cable AC-Adapter 7.1 Description of software booting Connect COM-port of PC with bootadapter using the enclosed RS232 cable. Afterwards plug in AC-Adapter, if connected correctly the „Power“ lamp will be active. Switch off handset and connect it to the bootadapter with the connection cable. Copy bootsoftware to your PC and follow the instructions in the „readme.txt“.
Private Communication Systems Mobile Phones Language Group Display Languages German, English, French, Italian Danish, Finish, Swedish, Norwegian English, Katalanish, Spanish, Portuguese English, Turkish, Czech, Polish English, Russian, Bulgarian, German English, Greek, Italian, Hungarian English, French, Dutch, SMS-CB English, French, Arabic, German b) PCN Language Group Display Languages...
Private Communication Systems Mobile Phones If you need unblocking codes just send a fax with the IMEI numbers to: Siemens AG PN KE SH World Service Center Bocholt, Germany Fax: +49 2871 91 3007 Please use the appropriate form provided by your service coordinator! 9 Battery 9.1 Specification...
Private Communication Systems Mobile Phones The S6 battery is a Lithium-Ion type with a voltage of 3.6 Volts and a capacity of 1000 mAh. The connections BATT+ and GND are used to supply the mobile, while RCODE is used to detect the battery technology. BATT_TEMP is used to measure the battery temperature.
This means that the character indicating the year 1997 will be a „J“ Example: TOS 8 J2 VA 1 This battery was produced in february of 1997! 10 S6 GSM / PCN Accessories V1.3 PN MP ST D. Schnoor 10/97...
Page 26
Private Communication Systems Mobile Phones Depicted are the following accessories: V1.3 PN MP ST D. Schnoor 10/97...
Private Communication Systems Mobile Phones 10.1 Desktop Charger This charger can be used to charge the battery alone or the battery inserted into the handset, but not both at the same time! Furthermore ist is helpful to reset disabled batteries. The desktop charger is supplied by the AC-adapter coming with the handset.
The connections to the battery are made directly using the cables with fuses for „battery+“, „battery-“ and „ignition“. Furthermore it provides a „radio mute“ connection to the car radio. See drawing „S6 GSM / PCN Accessories“ for details- 11 Spare Parts List List of spare parts / jigs and tools / swap units V1.3...