3-4. Charge Function Check
Note1: When perform this check, don't apply a voltage to battery terminals.
Note2: Be sure to disconnect the AC adapter when connecting the resistors.
Doing so with the power supply connected causes a trouble.
Procedure:
1. Connect the 10 ohms resistor (more than 3 watts) to battery
terminals.
2. Connect the AC adapter to the battery charging stand in
accessories and set the main unit.
3. Enter the test mode (Display Check mode).
4. Press the [VOL+] key to enter the Manual mode.
5. Press the [VOL+] key twice, press the
[VOL+] key once, press the
key twice to display as follows.
Display of the remote commander
250 ChrgLi
6. And
key once again to select the item number 2251 and
>
display "251 ChgChk **" on the LCD of remote commander.
7. Press the
,
ENT
+
u
remote commander confirm that "ADJ OK" is displayed.
8. Press the
key four times and back to the Display Check
x
mode.
9. Cut the power supply and remove the resistor that connected
to the battery terminals.
3-5. Laser Power Check
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Open the lid and press the
optical pick-up moves to the most inward track.
4. Press the [VOL--] key once to display as follows.
Display of the remote commander
009 DESIGN
5. Press the
key three times to select the item number 9111
>
and display as follows.
Display of the remote commander
111 LrefPw **
6. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser power meter at right
angle. (Confirm it with the disc not inserted)
7. Confirm that the value of laser power meter is 0.860 mW ±
19.2%.
8. Press the
key to select the item number 9112.
>
9. Confirm that the value of laser power meter is 0.763 mW ±
18.2%.
10. Press the
key to select the item number 9113.
>
11. Confirm that the value of laser power meter is 6.87 mW ±
12%.
12. Press the
key four times and back to the Display Check
x
mode.
key once, press the
>
key once, press the [VOL+]
>
key on the set or
key on the
key continuously until the
.
3-6. Setting The Adjustment Values
3-6-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (*3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
Kr × (−100)
0212
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
Kw × (−100)
0214
0215
Prmin / 0.05
0216
Pwmin / 0.05
*1) If the "Pr_nominal" value is indicated, use the "Pr_nominal" value
and not used "Por" value.
*2) If the "Pw_nominal" value is indicated, use the "Pw_nominal" value
and not used "Ppw" value.
*3) Round off after the decimal point.
Table 3-6-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No.
Parameter
0211
Pr_nominal
2.48 mW
−0.3 %/°C
0212
Kr
0213
Pw_nominal 7.35 mW
−0.4 %/°C
0214
Kw
0215
Prmin
1.9 mW
0216
Pwmin
5.8 mW
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
key once, press the [VOL+] key once, and press
3. Press the
>
the
key once again to display as follows.
>
Display of the remote commander
210 DiscPr
4. Press the
key once to select the item number 0211.
>
5. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
6. Press the
,
ENT
+
u
remote commander to write the adjusted value.
7. Press the
key to next item.
>
8. Repeat adjustment from step 4 until item number 0216.
MZ-DH10P
Result
Decimal
Hexadecimal
50
32h
30
1Eh
147
93h
40
28h
38
26h
116
74h
key on the set or
key on the
19