Pentair Pool Products GreatWhite User Manual page 12

Automatic pool cleaner
Hide thumbs Also See for GreatWhite:
Table of Contents

Advertisement

Available languages

Available languages

6
Standard Installation
The vacuum regulator must be installed in conjunction with the reducer cone (Figure 10). The reducer cone
is required to make most skimmer connections. It will keep the hose and vacuum regulator in place once
the filter system is stopped.
To install the vacuum regulator, insert the vacuum regulator and reducer cone in the skimmer. Attach the
end of the hose to the regulator (Figure 11).
Figure 11: Vacuum regulator installed in the skimmer with the hose attached
Make sure the vacuum regulator is submerged at all times. If not, the pump will suck air through the
vacuum regulator and lose prime. This could damage the pump.
Great White Installation and User's Guide
(Continued)
Figure 10
Skimmer
Vacuum
Regulator
Reducer Cone
To Pump

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greatwhite gw9500

Table of Contents