Electrical Adjustments

Service Adjustment Data Table

Group No. Adjustment Item
0
Thermal Monitor
0
LM76(Temp) A Monitor
1
LM76(Temp) B Monitor
2
LM76(Temp) C Monitor
1
Atmosphere Monitor
0
MPXA4114A(Pressure) Monitor
1
MPXA4114A(Pressure) Monitor
2
MPXA4114A(Pressure) Monitor
3
Acceleration Monitor
0
MAS1390 (Acceleration) Monitor
5
FAN Monitor (Read only)
FAN A Monitor (PBS)
FAN B Monitor (Lamp-IN)
FAN C Monitor (Lamp-Front)
FAN D Monitor (Power)
FAN E Monitor (Panel)
FAN F Monitor (Exhaust)
10
RS232C Setting
0
Baurate
1
Serial mouse switch
11
PJ-Net Setting
0
Reset Disable
20
Logo prohibition
0
Logo prohibition
30
Color Shading/Gamma
0
Color Shading Correction On/Off
1
Gamma Correction On/Off
40
Dimmer Control
1
Dimmer Level
2
DIMMER CTRL LEVEL1
3
DIMMER CTRL LEVEL2
4
DIMMER CTRL LEVEL3
5
DIMMER CTRL LEVEL4
6
DIMMER CTRL LEVEL5
7
DIMMER CTRL LEVEL6
8
DIMMER CTRL LEVEL7
9
DIMMER CTRL LEVEL8
10
DIMMER CTRL LEVEL9
11
DIMMER CTRL LEVEL10
12
DIMMER CTRL LEVEL11
13
DIMMER CTRL LEVEL12
14
DIMMER CTRL LEVEL13
15
DIMMER CTRL LEVEL14
16
DIMMER CTRL LEVEL15
17
DIMMER AVE POINT
50
Auto-Picture Control
0
Auto-Picture Control Forced OFF
70
COOLING
0
COOLING_TIME
1
80
Factory use
0
90
PJ Operation History
0
OPERATION_HISTORY_1
~
49
OPERATION_HISTORY_50
50
OPERATION_HISTORY Reset
91
PJ Failure History
0
Warning_Log_1
~
49
Warning_Log_50
50
Warning_Log Reset
112
Lamp Config
0
Lamp Config Change
113
Lamp Reset Counter
0
Lamp Reset counter
Initial Value
Range
Input source / Description
(Read only)
-
-
Sensor A for External IC1691
-
-
Sensor B for Lamp IC1816
-
-
Sensor C for Panel IC1814
(Read only)
-
-
Atmosphere sensor
-
-
Atmosphere sensor [unit: mmHg]
-
-
Atmosphere sensor [unit:hpa]
(Read only)
-
-
Current voltage of Fan (0.01V unit)
-
-
Current voltage of Fan (0.01V unit)
-
-
Current voltage of Fan (0.01V unit)
-
-
Current voltage of Fan (0.01V unit)
-
-
Current voltage of Fan (0.01V unit)
-
-
Current voltage of Fan (0.01V unit)
0
0 / 1
RS232C baurate (0: 19200 / 1: 9600)
0
0 / 1
Serial mouse setting (0: Enable / 1: Disable)
0
0 / 1
PJ-Net Reset (0: Enable / 1: Disable)
0
0 / 1
Logo prohibition (0: Menu / 1: Forced)
0
0 / 1
Color Shading Correction (0: Off / 1: On) Not memorized
0
0 / 1
Gamma Correction (0: Off / 1: On) Not memorized
15
0 ~ 15
0:250 ~ 15:300W Effect only 300W
7
0 ~ 255
Bright level1 data: Bright level1 when less than the value
14
0 ~ 255
Bright level2 data: Bright level2 when less than the value
21
0 ~ 255
Bright level3 data: Bright level3 when less than the value
28
0 ~ 255
Bright level4 data: Bright level4 when less than the value
35
0 ~ 255
Bright level5 data: Bright level5 when less than the value
42
0 ~ 255
Bright level6 data: Bright level6 when less than the value
49
0 ~ 255
Bright level7 data: Bright level7 when less than the value
56
0 ~ 255
Bright level8 data: Bright level8 when less than the value
63
0 ~ 255
Bright level9 data: Bright level9 when less than the value
70
0 ~ 255
Bright level10 data: Bright level10 when less than the value
77
0 ~ 255
Bright level11 data: Bright level11 when less than the value
84
0 ~ 255
Bright level12 data: Bright level12 when less than the value
91
0 ~ 255
Bright level13 data: Bright level13 when less than the value
98
0 ~ 255
Bright level14 data: Bright level14 when less than the value
105
0 ~ 255
Bright level15 data: Bright level15 when less than the value
4
1 ~ 16
Average point data for dimmer 1~16 4
0:follows to Menu, 1:Forced OFF
Cooling time period after power off
Not used
0
0 ~ 32767
Operation history in last operation
0
0 ~ 32767
Operation history in last 50th operation
0
0 ~ 10
It resets the history when the value is changed to 10.
0
0 ~ 32767
Operation history in latest operation
:
:
0
0 ~ 32767
Operation history in latest 50th operation
0
0 ~ 10
It resets the history when the value is changed to 10.
2500
1000 ~ 8000
Lamp life selection (Step: 500H)
(Read only)
0
0 ~ 127
Reset times of the lamp time counter
- 30 -
These initial values are the reference data written from the CPU
ROM to memory IC when replaced new memory IC. The adjust-
ment items indicated with "✻" are required to readjust following
to the "Electrical adjustments". Other items should be used with
the initial data value.