Induction Cooktop Installation

Multiple Cooktop Installation
IMPORTANT NOTE: Unframed induction cooktops are not
designed to be installed in combination with other
cooktops.
If the framed induction cooktop is to be used with any
combination of additional cooktops or modules with a filler
strip, the dimensions provided in the chart below are
1
derived by adding 1
/
" (32) additional space for each
4
additional unit, to give you the total countertop cut-out
width. Dimensions include the filler strip.
IMPORTANT NOTE: For model CT15I/S, the cut-out width
should be increased from 13
installed with multiple cooktops.
When multiple cooktops are installed side by side, each
unit must have its own separate recommended electrical
circuit.
When two or more modules are installed together, an
integrated module filler strip is recommended. If a 30"
(762) downdraft ventilation system is also installed, an
integrated module support for downdraft ventilation is also
required.
The filler strip and other accessories are available through
your authorized Wolf dealer. To obtain local dealer informa-
tion, visit the find a showroom section of our website,
wolfappliance.com.
Multiple Cooktops
COUNTERTOP CUT-OUT
2 Modules
3 Modules
4 Modules
30"
Cooktop / Module
(762)
30"
Cooktop / 2 Modules
(762)
36"
Cooktop / Module
(914)
3
/
" (340) to 14" (356) when
8
WIDTH
1
29
/
"
4
1
44
/
"
(1130)
2
3
59
/
"
(1518)
4
1
44
/
"
(1124)
4
1
59
/
"
(1511)
2
1
50
/
"
(1276)
4
Unframed Installations
Unframed induction cooktops can be mounted flush with
the top of the countertop or as a frameless installation
with the glass-ceramic top mounted on top of the counter-
top surface. In either installation the countertop cut-out
dimensions are the same. If the cooktop is to be mounted
flush with the countertop, a recessed area surrounding the
countertop cut-out must be provided. Refer to the installa-
tion illustrations on pages 10–11.
IMPORTANT NOTE: An installation kit and additional
instructions required for a flush mount installation are
provided with the unframed induction cooktop.
Flush mount installations are intended for granite, solid
surface or stone countertop surfaces only. Contact
with hot cookware may cause damage to countertop
surfaces that are not resistant to high heat.
(743)