Connecting The Cable Between Indoor Unit And Outdoor Unit - LG TMNC092DYAA Service Manual

Multi type air conditioner
Table of Contents

Advertisement

Connecting the cable between indoor unit and outdoor unit

Connecting the cable between indoor unit and outdoor unit
Connect the cable to the Indoor unit.
Connection of the cable
1. Remove the cover control from the unit by loosening the screw.
Connect the wires to the terminals on the control board individually as the following.
2.Secure the cable onto the control board with the hold-
er (clamper).
3.
screw.
4.Use a recongnized circuit breaker between the power
source and the unit. A disconnection device to ade-
Outdoor unit
Terminal block
Over 5mm
Holder for
power supply
cord
Cover control
Connecting cable
Power cord
Service Manual 47