Wolf ICBCT15G Installation Instructions Manual page 8

Gas cooktops
Table of Contents

Advertisement

W O L F
I N S TA L L AT I O N
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model ICBCT36G/S.
IMPORTANT NOTE: 991 mm wide cabinets are
recommended for installation of Model
ICBCT36G/S.
A Wolf 914 mm built-in oven may be installed
below Model ICBCT36G/S. For this installation,
unless you are using cabinets deeper than
610 mm, it is recommended that the electrical
and gas supply be placed in the base cabinet to
the right of the oven. Refer to installation
instructions provided with the built-in oven for
additional specifications.
I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L I C B C T 3 6 G / S
762 mm
914 mm
OVERALL WIDTH
OVERALL WIDTH
Overall Dimensions
M O D E L I C B C T 3 6 G / S
D I M E N S I O N S
Overall Width
Overall Height
Overall Depth
Recommended
Cabinet Width
Minimum Cabinet Depth
Minimum Height Clearance 102 mm
Cut-Out Width
Cut-Out Depth
Unit dimensions may vary to ± 3 mm.
8
G A S C O O K T O P S
S P E C I F I C A T I O N S
533 mm
533 mm
OVERALL
OVERALL
DEPTH
DEPTH
102 mm
330 mm
max
64**
489 mm
mm
COOKTOP CUT-OUT
102 mm
DEPTH
610 mm
min
914 mm
102 mm
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop.
533 mm
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
Note A:
991 mm
Side clearances. If the distance
578 mm
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
889 mm
clauses 5.12.1.1. & 5.12.1.2 of AS5601.
Note B:
489 mm
The rangehood fitted above the
cooktop must be installed according to
the installation instructions for the
rangehood. A minimum distance of
750 mm is required for a range hood
and 750 mm for an exhaust fan
If the Model ICBCT36G/S is installed above
cabinets, the gas and electrical placement is not
critical. A grounded outlet needs to be placed
within 1.2 m of the right rear of the cooktop.
When a 914 mm built-in oven is installed below
Model ICBCT36G/S, it is recommended that the
rough opening for the oven be 197 mm from
the floor to ease the use of the oven door.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
229 mm*
min
457 mm
CUT-OUT TO
COMBUSTIBLE
64 mm
Note A
MATERIALS
min
(BOTH SIDES)
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
64 mm
min
.
991 mm
762 mm
RECOMMENDED CABINET WIDTH
914 mm
min
COUNTERTOP TO
Note B
COMBUSTIBLE
889 mm
MATERIALS
COOKTOP CUT-OUT WIDTH
ABOVE COOKTOP
102 mm
E
G
89 mm
95 mm
254
min
mm
914 mm OVEN OPENING
889 mm
COOKTOP CUT-OUT WIDTH
489 mm
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
Countertop Cut-Out