Wolf ICBCT15G Installation Instructions Manual page 7

Gas cooktops
Table of Contents

Advertisement

I N S TA L L AT I O N
I N S T R U C T I O N S
I N S TA L L AT I O N
S P E C I F I C A T I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model ICBCT30G/S.
IMPORTANT NOTE: 838 mm wide cabinets are
recommended for installation of Model
ICBCT30G/S.
A Wolf 762 mm single built-in oven may be
installed below Model ICBCT30G/S. For this
installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical and gas supply be placed in the
base cabinet to the right of the oven. Refer to
installation instructions provided with the built-
in oven for additional specifications.
I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L I C B C T 3 0 G / S
533 mm
533 mm
OVERALL
OVERALL
DEPTH
DEPTH
762 mm
762 mm
102 mm
OVERALL WIDTH
OVERALL WIDTH
102 mm
Overall Dimensions
M O D E L I C B C T 3 0 G / S
D I M E N S I O N S
Overall Width
Overall Height
Overall Depth
Recommended
Cabinet Width
Minimum Cabinet Depth
Minimum Height Clearance 102 mm
Cut-Out Width
Cut-Out Depth
Unit dimensions may vary to ± 3 mm.
If the Model ICBCT30G/S is installed above
cabinets, the gas and electrical placement is not
critical. A grounded outlet needs to be placed
within 1.2 m of the right rear of the cooktop.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
330 mm
max
64**
489 mm
mm
COOKTOP CUT-OUT
DEPTH
610 mm
min
762 mm
102 mm
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop.
533 mm
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
Note A:
838 mm
Side clearances. If the distance
measured from the periphery of the
578 mm
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
clauses 5.12.1.1. & 5.12.1.2 of AS5601.
737 mm
Note B:
489 mm
The rangehood fitted above the
cooktop must be installed according to
the installation instructions for the
rangehood. A minimum distance of
750 mm is required for a range hood
and 750 mm for an exhaust fan
229 mm*
min
457 mm
CUT-OUT TO
COMBUSTIBLE
Note A
64 mm
MATERIALS
min
(BOTH SIDES)
95 mm
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
64 mm
min
.
Countertop Cut-Out
838 mm
RECOMMENDED
762 mm
CABINET WIDTH
762 mm
min
COUNTERTOP TO
Note B
COMBUSTIBLE
737 mm
COOKTOP
MATERIALS
CUT-OUT WIDTH
ABOVE COOKTOP
102 mm
E
G
89 mm
254
min
mm
762 mm OVEN OPENING
737 mm
COOKTOP CUT-OUT WIDTH
489 mm
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents