Plan The Ductwork - Viking VIPR182R Instruction Manual

Hide thumbs Also See for VIPR182R:
Table of Contents

Advertisement

Available languages

Available languages

VIKING RANGE, LLC
TAKE MEASUREMENTS
Interior Blower Installation
SIDE VIEW
7 "
OF DOWNDRAFT
WITH
3 "
VIDV500
INTERIOR
BLOWER
18"

PLAN THE DUCTWORK

Interior Blower Installation
1. The interior down-
draft blower system is
designed for use with
3-1/4" x 10" duct-
work (can be transi-
tioned to 6" round).
Three different dis-
charge directions are
available with side-to-
side adjustment for
accurate alignment of
ductwork.
2. For best perfor-
mance: Choose the
ducting option which
allows the shortest
length of ductwork
and a minimum number of elbows and transitions. Check
location of fl oor joists, wall studs, electrical wiring or
plumbing for possible interference.
3-1/4" X 10" TO 6" RD.
6" ROUND
TRANSITION
ELBOW
EQUALS
EQUALS 6 FT. OF
2 FT. OF
STRAIGHT DUCT
STRAIGHT DUCT
3. The system will operate most effi ciently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
(CONTINUED)
2"
1
"
1"
4
11
2 "
1
16
1
3 "
8
4
5
8
5
29 "
16
FROM
COUNTERTOP
5"
TO BOTTOM
OF AIR BOX
VIDV500
VIDV500
INTERIOR
INTERNAL
BLOWER
BLOWER
LEFT
DISCHARGE
DISCHARGE
DOWN DISCHARGE
3-1/4" X 10"
O
90
EQUALS 8 FT. OF
STRAIGHT DUCT
Exterior Blower Installation
SIDE VIEW
OF DOWNDRAFT
10" ROUND ELBOW
(for connection
to VEDV900 or
VEDV1200 Exterior
Exterior Blower Installation
1. The exterior downdraft
blower system is designed
for use with 10" round
ductwork.
2. For best performance:
Plan ducting which has the
shortest length of ductwork
and a minimum number of
elbows. Check location of
fl oor joists, wall studs, elec-
trical wiring or plumbing
for possible interference.
RIGHT
10" ROUND
ELBOW
3. The system will operate most effi ciently when the ductwork
does not exceed 40 feet of equivalent duct. The illustration,
above, shows equivalent feet of a 10" round elbow. The
number of feet of straight duct plus the equivalent feet of
elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
3
Downdraft Ventilators
WITH
3
3 "
16
Blower)
1
"
13
4
9
1 "
16
ELBOW
2"
1
"
1"
4
11
7 "
2 "
1
16
1
3 "
8
4
5
3 "
8
5
29 "
16
FROM
COUNTERTOP
TO BOTTOM
10" ROUND
OF AIR BOX
ELBOW
1
"
13
4
10" ROUND
DISCHARGE
PLATE
EQUALS 6 FT. OF
STRAIGHT DUCT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vipr182Vipr162Vipr162rVipr102rVipr102

Table of Contents