Trouble Shooting

If any problem occurs, please detach the plug from the socket
and contact Euro-Parts or a similarly qualified person in order
to avoid a hazard.
Fan does not turn on (but light turns on).
This is probably due to either a defective fan switch or a
burned out fan motor. Both can be replaced without
removing the range hood from the wall or cabinet. Use an
ohm meter to determine which component is not working. If
the ohm meter reads that the fan switch has 0 ohms of
resistance, then it is the motor that needs to be replaced. If it
reads anything other than zero, then the switch must be
replaced.
Fan only runs at one speed.
Please see above instructions.
Fan circulates air, but does not vent outside.
If air is blowing through the front vent openings, then your
range has been installed for ductless operation. In order to
convert the system to vent outside, a technician must install
ductwork from the range hood through either an outside wall
or the roof.
If air is not blowing from the front vent openings, check inside
the cabinet around the range hood. If you see a duct leading
away from the vent hood, then you have a system that vents
to the outdoors. If you do not see a duct, your unit may be
venting through the back wall.