Yale 7402 2 Wire Video Intercom System USER MANUAL User Setup (1) Door Station Call Tone ... Intercom Call Tone ... DoorBell Tone ... Clock ... Next Page ... Select Item About Exit YDV7402-V1...
Power Unit 1. Warning - Don’t dismantle or alter the unit. Fire or electric shock could result. - The unit must be installed and wired by a qualified technician. - Do not connect any non specified power source to the N, L terminals, Fire, damage to the unit, or system malfunciont can result.
Page 3
4. Mounting: Step1: Mount the din rail to the wall with screws ; Step2: Pull down the lock release lever,then hang the unit on din rail. Din rail Din rail Lock release lever 5. Basic wiring (no lock): (DS) (IM) NP: Non-polarized Note:PA&P+ terminal must be short-circuited.
Exterior Unit 1.Parts and Functions Camera Lens Night View LED Speaker Nameplate Call Button Microphone Rain Cover 90 mm 23 mm 2.Terminal Descriptions 1 2 3 Lock Control Jumper Doorstation Code DIP MIC adjustment SPK adjustment Main Connect Port S 2 + S - P L S 1 + B U S YDV7402-V1...
Page 5
• Lock Control Jumper: Not to be removed • Doorstation Code DIP: To be used when additional exterior units are used in the same system. • Main Connect Port: To connect the interior monitor and electornic lock/s. BUS: Connection to interior monitor, no polarity. PL: External lock power input, connect to the power positive(power +).
5. Placing Name Label Remove the plastic cover to open the transparent name label holder, cut a paper to size print name. Insert paper on to name holder re insert plast cover back to the panel Backside name label 6. Adjusting Camera Angle Use a screwdriver to loosen the screw.
Page 7
7. Basic wiring (with electronic lock) monitor BUS(IM) BUS(DS) BUS PLS1+ S2+ S- BUS(DS) BUS(IM) Use supplied plugs to connect Exterior unit to Power unit, and Power Unit ot Interior Monitor. YDV7402-V1...
Interior Monitor 1. Parts and Functions Digital TFT LCD screen UNLOCK(▲) button MONITOR(▼) button INTERCOM(●) button TALK(◄) button MENU(►) button Microphone Mounting hook Speaker Connection Port DIPS 1 2 3 4 5 6 Mounting hook 2. Monitor Mounting 1. Use the scrwes to fix the mounting bracket on the mounting box. Fitting accesories include a bracket (Two 4X25 screws are needed for fastening the mouting bracket), 2 wire adaptor to connect with Monitor and cable.
3. Basic Door Release Operation 1. Press CALL button on outdoor station, the DS-1 00:23 Monitor rings, at the same time, the screen displays the visitor image. 2. Press TALK ( ) button on monitor, you can communicate hands free with the visitor for 90 seconds.After finishing communication,press "TALK"...
: User in one apartment can call Intercom Call Intercom Call other apartments in the system. The namelist will be [ 00 ] Alex [ 01 ] created automatically by the system. Selete a name [ 02 ] [ 03 ] Alice MENU ( on the screen then press...
6. Date and Time Setting Select item on User Setup (1) page. Clock... Clock Input date and time by pressing ▲ / ▼ button to increase / decrease the value; press 2011- 04 - 22 17:17 button to select last/next digit. Press INTERCOM ( ) button to save and return Inc/Dec Save&Exit...
Page 12
How to set secundary/slave monitors to view image when call is made In default mode and when receiveing a call, the master and slave monitors will ring at the same time, but just the master monitor will display the image, while the slave monitors will not.
Language mode setting This monitor can support multi languages. T o c h a n g e t h e l a n g u a g e , input the corresponding language code. The language code number are as follows: 8101: English 8107: Portuguese 8113: Russian...
9. Monitor Time Setting While in monitoring mode, press INTERCOM button and use to navigate ▲ / ▼ to Monitor Time Set Option. Press MENU button to enter. ▲ / ▼ button to increase/decrease value and MENU button to save Monitor Time Select Current : 01min...