  • Page 2: Power Unit

    Power Unit 1. Warning - Don’t dismantle or alter the unit. Fire or electric shock could result. - The unit must be installed and wired by a qualified technician. - Do not connect any non specified power source to the N, L terminals, Fire, damage to the unit, or system malfunciont can result.
  • Page 3 4. Mounting: Step1: Mount the din rail to the wall with screws ; Step2: Pull down the lock release lever,then hang the unit on din rail. Din rail Din rail Lock release lever 5. Basic wiring (no lock): (DS) (IM) NP: Non-polarized Note:PA&P+ terminal must be short-circuited.
  • Page 4: Parts And Functions

    Exterior Unit 1.Parts and Functions Camera Lens Night View LED Speaker Nameplate Call Button Microphone Rain Cover 90 mm 23 mm 2.Terminal Descriptions 1 2 3 Lock Control Jumper Doorstation Code DIP MIC adjustment SPK adjustment Main Connect Port S 2 + S - P L S 1 + B U S YDV4202-V1...
  • Page 5: Specification

    • Lock Control Jumper: Not to be removed • Doorstation Code DIP: To be used when additional exterior units are used in the same system. • Main Connect Port: To connect the interior monitor and electornic lock/s. BUS: Connection to interior monitor, no polarity. PL: External lock power input, connect to the power positive(power +).
  • Page 6: Placing Name Label

    5. Placing Name Label Remove the plastic cover to open the transparent name label holder, cut a paper to size print name. Insert paper on to name holder re insert plast cover back to the panel Backside name label 6. Adjusting Camera Angle Use a screwdriver to loosen the screw.
  • Page 7 7. Basic wiring (with electronic lock) monitor BUS(IM) BUS(DS) BUS PLS1+ S2+ S- BUS(DS) BUS(IM) Use supplied plugs to connect Exterior unit to Power unit, and Power Unit ot Interior Monitor. YDV4202-V1...
  • Page 8: Parts And Function

    Interior Monitor Introduction The monitor is designed with a 4 inch screen, it provides a resolution of 320x240 pixels with high quality image display, and it is equipped with a handset to communicate The touch sensitive button makes the operation easy. Parts and Function Microphone Mounting Hook...
  • Page 9: Unit Mounting

    Unit Mounting Accessory contents: , t e , ) t 2 wire plug/connectors (use to connect with Monitor). Installation steps: Installation height for indoor monitor usually is 145~160cm (refer to sketch). Wire the cable correctly, then hang the Monitor on mounting bracket firmly. About Main Menu Main Menu The main menu is your starting point...
  • Page 10: Entrance Monitoring

    • Pick up handset to talk with the visitor, the talking duration time is 90s. To en the conversation, hang up the handset. If the system connects two or more monitors, puck up any handset, the others will be automatically shut off. Door Release During a call, press UNLOCK button to open the door for the visitor.
  • Page 11: Ring Tone Setting

    Direct Call Guard unit: A Monitor can be assigned as Guard Unit Monitor, so a intercom call can be placed directly to the Guard Unit Monitor. Intercom Intercom Call [ 00 ] Intercom Call ... [ 01 ] Alex Inner Call ... [ 02 ] Mike Direct Call Guard Unit ...
  • Page 12: Screen Setting

    Screen Setting Scene Brightly Bright During a c a l l o r w h e n monitoring ouside, press Color Select Camera ... MENU button, the adjust menu will be displayed. button to select the adjust menu item, Exit Select Item use M E N U button to change values.
  • Page 13: Unlock Time

    How to set the monitor as a Guard Monitor A Monitor can be assigned as Guard Unit Monitor. A call can be placed directly to the Guard Unit Monitor, bypassing the Intercom Menu. The code 8004 is used to set the monitor as a guard unit monitor and 8005 to cancell this function.
  • Page 14 2 locks control: The monitor can be set to control 2 locks while you should set the unlock2 item to "on " state. The code number of 8015 is used to set the unlock2 OFF. This setting is for only one lock. The code number of 8014 is used to set the unlock2 ON.
  • Page 15 How to set the address for monitor Each monitor should be assigned an address in the system, total 32 address- es can be assigned. Code numbers from 8200 to 8231 are used as address 00 to 31. Please refer to following table: Input No.
  • Page 16: Specifications

    Specifications • Power Supply: DC 24V • Power Consumption: Standby 6mA; Working status 194mA • Monitor Screen: 4 Inch color LCD • Display Resolutions: 320(R, G, B) x 240 pixels • Video Signal: 1Vp-p, 75Ω, CCIR standard • Wiring: 2 wires, non-polarity •...