Prime Chiller
Modular Upgradable Chiller
Instructions for Models
Single Stage Thermostat #2604, 2606
Dual Stage Thermostat #2614, 2616
Single Stage Thermostat w/ TXV #2626, 2627
Chiller Installation ....... Page 4
Warranty ....... Page 9
EMAIL:INFO@CURRENT-USA.COM
WWW.CURRENT-USA.COM
02-2007-JEE

Advertisement

loading

Summary of Contents for Current Prime Chiller 2604

  • Page 1: Table Of Contents

    Prime Chiller ™ Modular Upgradable Chiller Instructions for Models Single Stage Thermostat #2604, 2606 Dual Stage Thermostat #2614, 2616 Single Stage Thermostat w/ TXV #2626, 2627 Warning and Safety Instructions ..Page 2 Chiller Installation ..Page 4 Temperature Controller Installation ..Page 6 Programming Temperature Controller ..
  • Page 2: Warning And Safety Instructions

    In the event that you are experiencing trouble running your chiller, please visit our website support section at www.current-usa.com or contact Current-USA directly at 866-276-8872 for troubleshooting assistance. Please have the following information available:...
  • Page 3: Safety Instructions

    To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself. Contact Current-USA or discard the appliance. • If the appliance falls into the water, or water drips onto the unit, DON’T reach for it! First unplug it and then retrieve it.
  • Page 4: Chiller Installation

    Use the supplied piece of cork tape to hold the sensor in place by wrapping the tape around the entrance to the sensor port. This will isolate the temperature sensor from ambient heat. WWW.CURRENT-USA.COM...
  • Page 5 30 minutes to ensure adequate water flow and no leaks. 7. Tilt the chiller from the back to allow any trapped air to escape from the evaporator housing. You may need to do this a few times until all of the air has escaped. WWW.CURRENT-USA.COM...
  • Page 6: Temperature Controller Installation

    Use the supplied piece of cork tape to hold the sensor in place by wrapping the tape around the entrance to the sensor port. This will isolate the temperature sensor from ambient heat. Chillers must use controllers supplied by Current-USA, Inc. Use of any other controller will void the chiller warranty.
  • Page 7: Programming Temperature Controller

    H1. To operate a chiller thermostat must be set to C1. To operate a heater, thermostat must be set to H1. The factory setting is C1. Proceed to #5 for Dual Thermostats or press the SET key again to view current temperature and resume the normal operating mode.
  • Page 8: Troubleshooting/Maintenance

    In addition, circulating a diluted hard water stain remover through the evaporator will help remove deposits that can affect the chiller’s performance. Be sure to rinse well with freshwater and let dry before re-installing the chiller on your system. WWW.CURRENT-USA.COM...
  • Page 9: Warranty

    If you discover a defect, please see your retail store or point of purchase. Current USA, Inc. will, at it's option, repair or replace the product at no charge to you, provided you return it during the warranty period.