Specifications; Package Contents; Troubleshooting - Cool-Living CL-PAC121 Operating Instructions Manual

12,000 btu portable air conditioner
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSES
The air conditioner is unplugged or not
The Air Conditioner will not start
connected well.
The fuse is blown/circuit breaker is
tripped.
Power Failure
The current interrupter device is
tripped.
Airflow is restricted
The Air Conditioner does not cool
as it should
The temperature control may not be
set correctly.
The air filter is dirty
The room may be too warm
Cold air is escaping
The Evaporator is frozen
The Dehumidifier function is not
providing cool air as it should
The Air Conditioner displays the
Is the TIMER ON enabled?
Timer hours but does not work
The batteries are inserted incorrectly
The Remote Control is not working
The batteries may be dead
14
SOLUTIONS
Make sure the air conditioner plug
is pushed completely into the out-
let
Check the house fuse/circuit
breaker box and replace the fuse
or reset the breaker.
The unit will automatically re-start
when power is restored.
There is a protective time delay
(approx. 3 minutes) to prevent
tripping of the compressor
overload. For this reason, the unit
may not start normal cooling for 3
minutes after it is turned back on.
Press the RESET button located
on the power cord plug.
If the RESET button will not stay
engaged, discontinue use of the
air conditioner and contact a
qualified service technician.
Make sure there are no curtains,
blinds, or furniture blocking the
front of the air conditioner
Lower the set thermostat tempera-
ture
Clean the filter. See the Cleaning
and Care Section of the manual.
Please allow time for the room to
cool down after turning on the air
conditioner.
Check for open furnace registers
and cold air returns
The unit is defrosting and will re-
sume operation when done.
Cancel the TIMER or wait until the
unit turns on.
Check the position of the batteries.
Replace the batteries
14

PACKAGE CONTENTS

Portable Air Conditioner
Exhaust Hose (1)
Front Exhaust Hose Adapter (1)
Window Kit Adapter (1)
Rear Exhaust Hose Adapter (1)
Remote Control & AAA Batteries (2 batteries)
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)
Owner's Manual

SPECIFICATIONS

The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
If the environment temperature is higher than the max operating temperature or lower than the minimum operating
temperature, the air conditioner may not work properly.
Dehumidifier mode works when ambient temperatures are between 61°F - 86°F
Air Conditioner mode operates up to an ambient temperature of 95°F.
Model
Power Supply (Ph/V/Hz)
Dehumidifying Capacity (Pints/Day)
Rated Cooling Capacity (BTU/h)
Rated Heating Capacity (BTU/h)
Cooling Power Input (Watts)
Heating Power Input (Watts)
Rated Current Cooling (Amperage)
Rated Current Heating (Amperage)
Noise Level (dBA) - H/M/L
Air Flow - H/M/L (CFM)
Product Dimensions (W" x H" x D")
17.75 x 33.125 x 17.125
Product Weight (Lbs)
Refrigerant Type
CL-PAC-121
CL-PAC-122 (with Heat)
1/115/60Hz
1/115/60Hz
81.6
81.6
12,000
12,000
-
10,500
1465
1465
-
1200
13
13
-
10.6
55/53/51
55/53/51
235/205/175
235/205/175
17.75 x 33.125 x 17.125
80
80
R-410A
R-410A
CL-PAC-121_122
3
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl-pac122

Table of Contents