Air Conditioning Input; A/C Wiring Diagram - SPAL FAN-PWM-V3 Instructions For Use Manual

Electric fan controller
Table of Contents

Advertisement

Air Conditioning Input

The FAN-PWM has a built in 15 second delay for ON and a 30 second delay for
OFF with the Air Conditioning Input. After the A/C compressor has turned ON,
the fan will not go to HIGH until after a 15 second delay. After the A/C turns off,
the fan will stay on HIGH for 30 seconds before resuming normal operation.
1. If your A/C system does not have a trinary switch, connect the Blue wire

A/C Wiring Diagram

directly to the +12V wire of the air conditioning compressor or a wire within
your HVAC system that is powered only when the A/C is engaged. As a
result any time the compressor is engaged and or the A/C is activated, the
fan(s) will run at 100% with 'FAN' LED lit GREEN.
AIR CONDITIONING INPUT (BLUE)
9
GROUND
+12VDC WHEN A/C ON
www.spalusa.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents