Airflow Direction - Panasonic CS-E10HB4EA Service Manual

Hide thumbs Also See for CS-E10HB4EA:
Table of Contents

Advertisement

[Heating]
• According to indoor pipe temperature, automatic heating fan speed is determined as follows.
B. Feedback control
• Immediately after the fan motor started, feedback control is performed once every second.
• During fan motor on, if fan motor feedback
increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan motor error is detected.
Operation stops and cannot on back.
12.1.7. Outdoor Fan Motor Operation
Outdoor fan motor is operated with 15 fan speed. It starts when compressor starts operation and it stops 30 seconds after compres-
sor stops operation.

12.2. Airflow Direction

1. There is one type of airflow, vertical airflow (directed by horizontal vane).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger
temperature and intake air temperature) and manual (angles of direction can be adjusted using remote control).
12.2.1. Vertical Airflow
Operation Mode
Heating
Cooling
Soft Dry
2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error counter
Airflow Direction
Auto with Heat Exchanger
Temperature
Manual
Auto
Manual
Auto
Manual
44
1
A
Downward fix
B
Downward fix
C
Upward fix
D
Upward fix
20
20
20
Vane Angle (°)
2
3
4
5
70
70
20
20
33
45
58
70
20 ~ 70
33
45
58
70
20 ~ 70
33
45
58
70