Component Testing Tips - LG RC9011 Series Service Manual

Condensing dryer
Table of Contents

Advertisement

COMPONENT TESTING TIPS

7
Component
1. Thermostat
(Manual type)
2. Thermistor
(Low temperature )
3. Heater,
Thermistor
Thermistor
4. Motor
5. Capacitor
6. Pump
Test procedure
Measure resistance of
Terminal to terminal
1) Open at 170°C (-10/+5°C)
Measure resistance of
terminal to terminal
Measure resistance of
Terminal to terminal
Measure resistance of
therminal to terminal
Measure resistance of
Terminal to terminal
Measure capacitance of
Terminal to terminal
Measure resistance of
Terminal to terminal
Check result
Measure resistance by pressing
button When resistance becomes ∞
Resistance value < 5Ω
Resistance value :
10KΩ 5% (at 25°C)
Resistance value :
Yellow/White : 28.96 1Ω
Blue/White : 56.29 2Ω
Resistance value :
200KΩ 5% (at 25°C)
Resistance value(20°...):
Blue / White : 15.3( 7%)Ω
Red / White : 18.5( 7%)Ω
Capacitance value : 10 0.2µF
Resistance value(20°C):
210( 5%)Ω
14
Remark
Safety
Thermostat
Cover, Front
Heater

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc8011 series

Table of Contents