Operation Ranges - Samsung Wall Mounted Type Series User Manual

Air conditioner wall mounted type series
Table of Contents

Advertisement

appendix
PROBLEM
Remote control is
not working.
If the outdoor temperature is too low when heat mode is operating, special
operation will operate and it may make strange sound.It is normal operation
for the product safety.

OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
OPERATIONAL TEMPERATURE
MODE
INDOOR
60˚F to 90˚F
COOLING
(16˚C to 32˚C)
81˚F (27˚C)
HEATING
or less
60˚F to 90˚F
DRYING
(16˚C to 32˚C)
The standardized temperature for heating is 45˚F(7˚C). If the outdoor temperature drops to 32˚F(0˚C) or
below, the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 90˚F(32˚C)(indoor temperature), it does not cool at its full
capacity.
18_ appendix
SOLUTION
• Check if your batteries are depleted.
• Make sure batteries are correctly installed.
• Make sure nothing is blocking your remote control
sensor.
• Check that there are strong lighting apparatus near
the air conditioner. Strong light which comes from
fluorescent bulbs or neon signs may interrupt the
electric waves.
INDOOR HUMIDITY
OUTDOOR
23˚F to 118˚F
(-5˚C to 48˚C)
-4˚F to 75˚F
(-20˚C to 24˚C)
23˚F to 118˚F
(-5˚C to 48˚C)
IF OUT OF CONDITIONS
Condensation may occur on
the indoor unit with risk to have
80% or less
either water blow off or drops on
the floor.
Internal protection triggers and
-
the air conditioner will stop.
Condensation may occur on
the indoor unit with risk to have
-
either water blow off or drops on
the floor.