MediSure Blood glucose monitoring system User Manual

MediSure Blood glucose monitoring system User Manual

Hide thumbs Also See for Blood glucose monitoring system:

Advertisement

Medi Sure
Medi Sure
®
Blood Glucose Monitoring System
User Guide
(Multi-User Model)
Medi+Sure Canada Inc.
31A-328 Speedvale Ave. East, Suite 160,
Guelph , Ontario,
N1E 0J4, Canada.
www.medisure.ca
Toll Free: 1-855-MDI-SURE (634-7873)
Fax: 855-329-5302
E-mail: info@medisure.ca

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Blood glucose monitoring system and is the answer not in the manual?

Questions and answers

Summary of Contents for MediSure Blood glucose monitoring system

  • Page 1 Medi Sure Medi Sure ® Blood Glucose Monitoring System User Guide (Multi-User Model) Medi+Sure Canada Inc. 31A-328 Speedvale Ave. East, Suite 160, Guelph , Ontario, N1E 0J4, Canada. www.medisure.ca Toll Free: 1-855-MDI-SURE (634-7873) Fax: 855-329-5302 E-mail: info@medisure.ca...
  • Page 2: Table Of Contents

    ® Medi+Sure Multi-Patient User Guide - Table of Contents INTRODUCTION ....................... 1 TESTING PRINCIPLE ....................2 INDICATIONS FOR USE ..................... 3 IMPORTANT SAFETY INSTRUCTIONS ................ 4 CONTENTS AND SPECIFICATIONS ................5 Kit Contents ....................... 5 Meter Specifications ..................5 Test Strip Specifications ..................5 System Operating Conditions ................
  • Page 3: Introduction

    We thank you once again for your support. Before testing, please read this User's Guide thoroughly. It contains all the information you need regarding the Medi+Sure® Blood Glucose Monitoring System. If you have product related questions please call our Customer Assistance line at 1-855-634-7873 from 8:00 AM to 6:00 PM, Eastern Standard Time Monday through Friday.
  • Page 4: Testing Principle

    TESTING PRINCIPLE The Medi+Sure® Blood Glucose Monitoring System is designed to provide an easy, accurate method for determining capillary blood glucose values. This analysis is based on amperometric technology using glucose oxidase that is specific for the blood glucose measurement.
  • Page 5: Indications For Use

    INDICATIONS FOR USE The Medi+Sure® Blood Glucose Monitoring System is intended for use in the quantitative measurement of glucose in fresh capillary whole blood from the finger. It is to be used as an aid in monitoring the effectiveness of a Diabetes control program.
  • Page 6: Important Safety Instructions

     The Medi+Sure® meter should be disinfected after use on each patient. This Blood Glucose Monitoring System may only be used for testing multiple patients when Standard Precautions and the manufacturer’s disinfection procedures are followed.
  • Page 7: Contents And Specifications

    CONTENTS AND SPECIFICATIONS Kit Contents  Medi+Sure® Multi-Patient Blood Glucose Meter  3-Volt Lithium Coin Battery (CR2032)  User's Guide  Getting Started Guide  Carrying Case Meter Specifications Temperature: -20°~+50°C Humidity RH ≦ 80% Storage Conditions Memory Capacity 960 test results with respective dates and times Measurement Unit mmol/L Display...
  • Page 8: System Operating Conditions

    System Operating Conditions Test Strips Use only Medi+Sure Blood Glucose Test Strips Humidity: RH ≦ 80% Operating Conditions Temperature: 10°~40° C Sample Type Capillary whole blood in finger Hematocrit of 25%~60% Tested Blood To be used no higher than 10183 feet above sea Altitude Limit level The meter is calibrated to capillary whole blood equivalent results...
  • Page 9: About The Medi+Sure® System

    ABOUT THE Medi+Sure® SYSTEM Medi+Sure® LCD Display Show Blood Glucose Test Results and Messages Medi+Sure® Meter Back...
  • Page 10: Medi+Sure® Blood Glucose Test Strip

    Medi+Sure® Blood Glucose Test Strip How to determine whether blood sample is sufficient NOTE: If the sample is sufficient, the sampling window on the test strip should be full with no white space showing.
  • Page 11: How Your System Works

    HOW YOUR SYSTEM WORKS Installing or Replacing the Battery Your Medi+Sure® Blood Glucose Monitoring System is packed with one 3-volt lithium coin battery that needs to be installed before testing. The battery will last for approximately 1,000 tests. Always keep spare batteries on hand.
  • Page 12: Alarm Setting

    10. Press the button. The hour flashes. 11. Press the button or button until the correct hour is displayed. 12. Press the button. The minutes flash. 13. Press the button or button until the correct minutes are displayed. 14. Press the button.
  • Page 13: Reviewing Results In Memory

    Reviewing Results in Memory The Medi+Sure® Blood Glucose Meter automatically stores up to 960 test results with date and time. You can review test results from the newest to the oldest. Results stored in memory will not be lost when you replace the battery.
  • Page 14: Viewing Date, Time Or Temperature

    14. To delete all the results in the memory, press the button for at least 3 seconds. “----” message will be shown on the screen. This indicates that all results in the Memory have been deleted. If you don’t want to clear delete all test results, scroll to the individual result and press the button and the meter turns off.
  • Page 15: Alarm Notes

    Press the button and the temperature, and thermometer symbol will be shown on the screen for 3 seconds and the meter will turn off automatically. NOTE: To quickly adjust a certain number, keep pressing the button until the one you want appears. At any steps if you want to shut the meter off, press the button for about 3 seconds and all setting will be automatically saved.
  • Page 16: Blood Sampling And Testing

    BLOOD SAMPLING AND TESTING Finger Tip Blood Sampling 1. Wash hands in warm, soapy water. Rinse well and dry thoroughly. 2. Press a single use lancing device firmly onto the chosen site and draw a sufficient blood sample. 3. Dispose of lancet device in a suitable sharps container.
  • Page 17 automatically. You will hear a beep letting you know the countdown has begun. 7. Look at the sampling window on the test strip. If you have enough blood on the strip, you will not see any white. The sampling window will be completely filled with blood.
  • Page 18: Testing Control Samples

    Testing Control Samples Prepare the test strip and Glucose Control Solutions. 1. Press the button. The meter will power on. 2. Insert Medi+Sure® strip into the strip port. 3. Press the button to enter control mode. The button “L1” refers to Level 1. You can select L1, L2 or blood by pressing the button.
  • Page 19: How To Clean And Disinfect Your Device

    HOW TO CLEAN AND DISINFECT YOUR DEVICE Clean Before Disinfecting STEP 1: 1. Dispense CaviWipes towelette. 2. Clean surface of your device with towelette to remove debris and bioburden. 3. Discard used towelette. : Disinfect After Cleaning STEP 2 1. Dispense CaviWipes towelette. 2.
  • Page 20: Why Is The Disinfection Of This Device Required

    4. If the meter is being operated by a second person who is providing testing assistance to the user, the meter should be disinfected prior to use by the second user. 5. Wash hands thoroughly with soap and water after handling the meter, or test strips.
  • Page 21: Information Of Caviwipe Disinfectant

    Information of CaviWipe disinfectant CaviWipes Disinfecting Towelettes are purchased from METREX RESEARCH CORP, and the EPA Reg. is 46781-8. CaviWipes are non-woven disposable towelette pre-saturated with CaviCide, and are intended for use in health care settings such as hospital, dental offices, laboratories, clinics, ophthalmic offices, veterinary facilities and in kitchens and bathrooms.
  • Page 22: Important Notes

    3. Keep your meter free of dust. 4. It is recommended that you use the carrying case that is designed to store and protect your Medi+Sure® Blood Glucose Monitoring System. 5. Put your system in an appropriate operating environment at least 30 minutes before testing.
  • Page 23 No Memory in the Meter Message: If there is no memory in the meter, you press button two times and the meter shows “----”. Sample Application Message: This requires you to apply the blood sample or control solution to the test strip after inserting a test strip.
  • Page 24 HI Message: If the test result is higher than 41.7 mmol /L the “HI” message is displayed. Lo Message: If the test result is lower than 1.1 mmol /L the “Lo” message is displayed.
  • Page 25: Error Messages And Troubleshooting

    ERROR MESSAGES AND TROUBLESHOOTING When you operate the meter incorrectly, error messages are displayed. Each message is defined below. Cause: Test strip was removed during testing. Damaged or used test strip was used. The blood sample was applied before inserting the test strip.
  • Page 26 Cause: The system is operating outside the appropriate temperature range 10°~40°C. Action: Move your meter and test strips to a place where the temperature is appropriate for running a test. Wait at least 30 minutes and test again. Cause: The battery is low. Action: Replace the battery soon.
  • Page 27: Expected Values

    EXPECTED VALUES Expected blood glucose levels for people without diabetes: Time Range (mmol/L) Fasting < 7.0 Two Hours After Meal < 11.1 American Diabetes Association: Diabetes Care, Volume 35, Supplement 1, January 2012, S4...
  • Page 28: Meter Warranty

    METER WARRANTY Medi+Sure Canada Inc. warrants, to the original purchasers of the Medi+Sure® Blood Glucose Meter, that your meter shall be free of defects in materials and workmanships under a life time warranty from the date of purchase. If the Medi+Sure® meter does not work properly because of defects in materials or workmanships, Medi+Sure Canada Inc.
  • Page 29: Log Book

    Medi+Sure® Log Book TEST DATE TIME AC / PC NOTES/Patient Name RESULT...
  • Page 30 NOTES:...
  • Page 31 Personal Information Name Address Home Phone Mobile Phone Hospital Physician Email Diagnosis Date Additional Information:...

Table of Contents