2. Outdoor Unit

Cooling Only : AUUC186A/AUUC246A/AUUC306A
Cooling Only : AUUC368A/AUUC488A/AUUC608A
48 Universal System Air Conditioner

OUTDOOR WIRING DIAGRAM

PR
TMo
BR
POWER
1(L)
2
4
SUPPLY
BL
2(N)
6
8
220-240V~
50Hz
GN/YL
BL
BR
0
1
PR
OUTDOOR WIRING DIAGRAM
F1
BK
BK
BK
WH
RD
WH
OR
TMi
R
S T N
1
3
5
MC
CH
POWER SUPPLY
2
4
6
3Ø 380-415V~
BK
50Hz
BK
RD
BK
BK
RD
Co
Co
WH
T1
T2
(W)
(V)
T3
YL BK
YL BK
(U)
OR
OR
CM
FMo
FMo
BR
C
RD
COMP
S
BL
BL
R
Co
H
C
F
YL
OR
FMo
BK
RD
BL
FUSE(250V,5A)
BL
FUSE(250V,5A)
BR
TH
D.PWB
BK
NO NC
NO NC
TNS
WH
F1
WH
PR
BK
WH
1
2
OR
31
A
OR
3
4
T/B1
WH
5
6
B
7
8
32
T/B2
RD
BL
WH
WH
BK
WH
RD
BL
4WV
BL
GN/YL
NOTE
RD:RED
WH:WHITE
YL:YELLOW
BL:BLUE
BK:BLACK
BR:BROWN
OR:ORANGE
GN/YL:GREEN/YELLOW
FMo
OUTDOOR FAN MOTOR
Co
CAPACITOR
PR
POWER RELAY
D.PWB
DEICER PWB
TB
TERMINAL BLOCK
TMo
MAIN TERMINAL BLOCK
TMi
TERMINAL BLOCK
TH
THERMISTOR
WIRING OF FIELD
(CONNECTOR WIRING)
TMi
8
7
6
5
4(N)
3(L)
3854A20125M
NOTE
RD:RED
WH:WHITE
YL:YELLOW
BL:BLUE
BK:BLACK
BR:BROWN
OR:ORANGE
GN/YL:GREEN/YELLOW
FMo
OUTDOOR FAN MOTOR
Co
CAPACITOR
PR
POWER RELAY
D.PWB
DEICER PWB
TB
TERMINAL BLOCK
TMo
MAIN TERMINAL BLOCK
TMi
TERMINAL BLOCK
TH
THERMISTOR
WIRING OF FIELD
BK
(CONNECTOR WIRING)
1
(
L
)
2
(
N
)
3
4
5
TMo
3854A20125Q