Goodman GDH8 Series Technical Manual page 12

Gdh8 series 33-3/8" 80% gas furnace 80% afue, 2-stage (convertible), multi-speed, dedicated downflow
Table of Contents

Advertisement

FURNACE SPECIFICATIONS
MODEL
Btuh Input (US) High Fire
Output (US) High Fire
(1)
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
Pressure Switch Trip Point (" w.c.)
Blower Wheel (D" x W")
Blower Horsepower
Blower Speeds
Available AC @ 0.5" ESP
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transformer (VA)
Heat Anticipator (Amps)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Gas Supply Pressure (Natural/Propane) (" w.c.)
Manifold Pressure (Natural/Propane) High Stage (" w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Connector Diameter (inches)
Shipping Weight (lbs.)
1 DOE AFUE based upon Isolated Combustion System (I CS)
2 Vent and combustion air diameters may vary depending upon vent length.
Ref er to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149. 1
and CAN/CSA B142.2 (in Ca
3 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + I D Blower amps. Wire size should be det ermined in accordance with National Elect rical Codes.
Ext ens ive wire runs will require larger wire sizes.
4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circ uit breaker size. May use fuses or HACR-type circuit breakers of the same s ize as noted.
Notes:
• All furnaces are manufactured f or use on 115 VAC, 60 Hz, single-phase elect rical supply.
• G as Service Connect ion ½" FPT
• Important : Size fuses and wires properly and make electrical connections in ac cordance wit h t he National Elect rical Code and/ or all exis ting local codes.
NOTES:
*
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
*
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL
J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity.
Output based on D.O.E. test procedures, steady state efficiency times output.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information.
12
GDH80403 A*B*
(3)
(4)
(2)
GDH80603A*B*
40,000
60,000
32,000
48,000
80%
80%
.20 - .50
.20 - .50
25-55
30-60
-0.60
-0.60
10 X 6
10 X 6
1/3
1/3
4
4
3
3
115-60-1
115-60-1
8.5
8.5
15
15
40
40
0.7
0.7
180
180
120
120
300
300
7 / 11
7 / 11
3.5 / 10
3.5 / 10
#45 / #55
#45 / #55
2
3
4
4
88
92
GDH8***B*
GDH80804B*B*
GDH81005C*B*
80,000
100,000
64,000
80,000
80%
80%
.20 - .50
.20 - .50
35-65
40-70
-0.60
-0.80
10 X 8
10 X 10
1/2
3/4
4
4
4
5
115-60-1
115-60-1
12.9
12.9
15
15
40
40
0.7
0.7
180
210
120
120
300
300
7 / 11
7 / 11
3.5 /10
3.5 /10
#45 / #55
#45 / #55
4
5
4
4
106
114