Panasonic WV-SP509 Installation Manual page 26

Hide thumbs Also See for WV-SP509:
Table of Contents

Advertisement

v
Connect external devices to the EXT I/O terminal.
When connecting an external device, remove 9 mm - 10 mm
{11/32 inches - 13/32 inches} of the outer jacket of the cable
and twist the cable core to prevent the short circuit first.
Specification of cable (wire): 22 AWG - 28 AWG
• Check whether the stripped part of the wire is not exposed and is securely connected.
<WV-SP509>
r GND
e ALARM IN3 / AUX OUT
4 3 2 1
q ALARM IN1 / DAY/NIGHT IN
w ALARM IN2 / ALARM OUT
<WV-SP508>
IMPORTANT:
r GND
• Do not connect 2 wires or more directly to a terminal. When it is necessary to connect 2 or more
e AUX OUT
wires, use a splitter.
• Input and output of the EXT I/O terminal 2 and 3 can be switched by configuring the setting. "Off" is
selected by default. It is possible to determine whether or not to receive input from EXT I/O terminal 2
4 3 2 1
q ALARM IN
and 3 (ALARM IN2, 3) by selecting "Off", "Alarm input", "Alarm output" or "AUX output" for "Terminal
2" or "Terminal 3" on the [Alarm] tab on the "Alarm" page. Refer to the Operating Instructions (includ-
w ALARM OUT
ed in the CD-ROM) for further information.
• When using the EXT I/O terminals as the output terminals, ensure they do not cause signal collision
with external signals.
• Connect an external device with verifying that the ratings are within the specifications above.
• When using the EXT I/O terminals as the output terminals, ensure they do not cause signal collision
with external signals.
<Ratings>
• ALARM OUT, AUX OUT
Output specification: Open collector output (maximum applied voltage: 20 V DC)
Open: 4 V - 5 V DC by internal pull-up
Close: Output voltage 1 V DC or less (50 mA or less)
• ALARM IN / DAY/NIGHT IN*
Input specification: No-voltage make contact input (4 V - 5 V DC, internally pulled up)
OFF: Open or 4 V - 5 V DC
ON: Make contact with GND (required drive current: 1 mA or more)
* DAY/NIGHT IN is only for WV-SP509.
b
Connect a LAN cable (category 5 or better,
STP*) to the network connector on the rear of
the camera.
* E models only
26
<WV-SP509>
Single core, twisted
<WV-SP508>
r GND
e ALARM IN3 / AUX OUT
{11/32 inches - 13/32 inches}
4 3 2 1
q ALARM IN1 / DAY/NIGHT IN
w ALARM IN2 / ALARM OUT
r GND
e AUX OUT
4 3 2 1
q ALARM IN
w ALARM OUT
LAN cable
(This illustration represents
WV-SP509.)
Strip range
9 mm - 10 mm
10BASE T/100BASE-TX
AUDIO OUT
MIC/LINE IN
INITIAL
SET
ACT
LINK
SD CARD/ABF
POWER
MONITOR OUT
EXT I/O
12V = IN
GND 4 3 2 1
ALARM IN 1/DAY/NIGHT IN
ALARM IN 3/AUX OUT
ALARM IN 2/ALARM OUT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-sp508Wv-sp509eWv-sp508e

Table of Contents