2.5.13 Technical data

GENERAL
Model
RPM
Alternator
Engine
Number of cylinders
Displacement
Bore X stroke
Combustion air consumption
Continuous power engine
Cooling system
Cooling water pump
Fuel lift pump engine
Starting battery (optional)
Fuel consumption
Control
Sound level (ISO 3746):
ELECTRICAL SPECIFICATIONS
Output voltage
Output rating Whisper 8:
Output rating Whisper 10:
Voltage tolerance
Frequency tolerance
Alternator
Voltage regulation:
MECHANICAL SPECIFICATIONS
Supply includes
Dimensions hxwxd
Colour
Weight
Max. installation angle
Standard supplies
Optional:
14
The cooling liquid in the engine is pressurised and has a
boiling point above 100° C. The temperature switch in the
thermostat housing switches at 110° C. When keel cooling
or radiator cooling is applied the cooling system is not
pressurised. There should be a special cap on the
manifold without valves leaving the connection to the
expansion tank open. Refer to the manual on keel cooling
and radiator cooling.
WHISPER 8 / 10 ULTRA
1500
water cooled, synchronous
Mitsubishi diesel, model S3L2 (Japan)
3
1318 cm3
78x92 mm
1.3 m³/min.
Whisper 8 Ultra: 8 kW; Whisper 10 Ultra: 10 kW
indirect cooling by raw water, 18-22 l/min.
PTO driven Mastervolt self priming impeller pump, type M12
electric pump (12 V DC), additional pump available upon request
70 Ah 12V
2-4.5 litre/hour, load dependent
Digital Diesel Control including automatic start/stop
69.9 dB(A) (distance = 1 meter)
230V 50 Hz alternating current (AC) single phase
8 kVA = 8kW at power factor cos phi = 1
10 kVA = 10kW at power factor cos phi = 1
± 5%
Whisper 8 Ultra: ± 5%; Whisper 10 Ultra: ± 1%
brushless, four pole, synchronous
Capacitor
Sound shield with steel base, mounted on rubber anti vibration mounts. (Generator
set without sound shield is optional)
635 x 900 x 575 mm
top white, bottom green
340 kg including sound shield
25 degrees
Digital remote panel (+15 m cable), fuel filter, fuel lift pump, user and installation
manuals
Installation kits, mobile (vehicle) version, non earth return (ungrounded), spare
part kits, PTO to drive a hydraulic pump
December 2009 / WHISPER 8 & 10 ULTRA / EN / Copyright © 2009 Mastervolt