Generator Control Panel; Remote Control Panel; Technical Information; Ac Alternator - Mastervolt WISPER 8ULTRA 1500 RPM User Manual

1500 rpm marine diesel generating set 230v / 50hz digital diesel control
Table of Contents

Advertisement

INFORMATION
2.4.2

Generator control panel

Internal fuel pump
Digital Diesel Control
Fuse 3A
Fuse 3A
Remove fuse
before maintenance
Auxiliary
External Fuel Pump
Fuse 10A
Fuse 3A
Fig: 9 Control panel.
Fig. 10 Digital Diesel Control unit
6
5
7
Fig. 11: Digital Diesel remote control panel
2.4.3

Remote control panel

1
Start button;
2
Stop button;
3
Select button;
4
Set button;
5
Failure lamp;
6
Generator load indicator.
7
Display
12
Start / Stop
Whisper Digital Diesel Operation Unit
Observe instructions in the manual
Replace fuses with same type and rating
1
2
4
3
December 2009 / WHISPER 8 & 10 ULTRA / EN / Copyright © 2009 Mastervolt
2.5

TECHNICAL INFORMATION

2.5.1

AC alternator

The single phase alternator is directly coupled, one
bearing, brushless, rotating field design, four poles (1500
RPM) and self regulating.
Residual magnetism causes a small voltage over the
stator windings and allows a current to flow in the
windings, which is magnified because of the feed back
effect between rotor and stator. The field windings in the
rotor are short-circuited over a diode to rectify the current.
A capacitor over an additional winding in the stator which
is at an angle with the power-winding keeps the voltage
stable within 5 % at the specified rpm and provides voltage
fall off with speed, preventing over-excitation at low engine
speeds and softening the effect of load switching to relieve
the burden on the engine.
Further technical data on the design of the alternator can
be found in drawings and diagrams in this manual.
2.5.2

Engine

The Whisper 8 /10 ULTRA generating set is based on the
Mitsubishi S3L2 3 cylinder diesel engine. The engine is
indirectly injected. The engine is water cooled and the
cooling liquid is cooled by a heat exchanger and raw
water. The heat exchanger and all other parts which are in
direct contact with the raw (sea) water are made of
seawater resistant material like naval brass and gunmetal.
The engine has been specially adapted for the Mastervolt
application and is very different from the standard engine
supplied for industrial applications!
The Whisper 10 is almost identical to the Whisper 8. The
only difference is the electronic governor on the Whisper
10. Because of this electronic governor the Whisper 10
brings 2 kW more power than the Whisper 8.
2.5.3

Digital Diesel Control system

The standard electrical engine control system is 12 Volt
negative earth, non earth return (ungrounded) is available
as optional. Check your identification data to determine
which system is applied. The system is designed
according to the "energise to run" system. The Digital
Diesel Control is a very advanced microprocessor based
full automatic system. Besides automatic start the system
offers many monitoring options. Refer to the separate
Digital Diesel Control users manual.
The microprocessor unit is located in the black box on top
of the alternator
2.5.4

Battery charger

On the engine is an alternator generating 50 Amp 12V.
This current is rectified to charge the battery. The voltage
is regulated at ±14.4V.

Hide quick links: