All Weather Inc AWOS 3000 Installation And Checkout Manual

Automated weather observing system
Hide thumbs Also See for AWOS 3000:
Table of Contents

Advertisement

Automated Weather Observing System
Installation
and
Checkout
Manual
3000-017
Rev. C
All Weather Inc. • 1165 National Drive • Sacramento, CA 95834 • USA • 800.824.5873 • www.allweatherinc.com
FAA APPROVED
×
ECP180 — 2011 May 5
NOT FAA APPROVED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWOS 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for All Weather Inc AWOS 3000

  • Page 1 Automated Weather Observing System Installation Checkout FAA APPROVED × ECP180 — 2011 May 5 Manual NOT FAA APPROVED 3000-017 Rev. C All Weather Inc. • 1165 National Drive • Sacramento, CA 95834 • USA • 800.824.5873 • www.allweatherinc.com...
  • Page 2 Copyright © 201 , All Weather, Inc. All Rights Reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service All Weather, Inc. manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of All Weather, Inc.
  • Page 3: Table Of Contents

    C O N T E N T S AWOS 3000 INSTALLATION AND CHECKOUT T able of Contents 1. USING THIS MANUAL ............1 7. MODEL 2040 ULTRASONIC WIND SENSOR ....58     General Precautions ............1 Installation Guidelines ..........58  ...
  • Page 4 C O N T E N T S AWOS 3000 INSTALLATION AND CHECKOUT 14. MODEL 6500 THUNDERSTORM/LIGHTNING SENSOR 91 14.1 Overview ............... 91 14.2 RFI/EMI Precautions ............. 91 14.3 Sensor Installation............92 14.4 Checkout ............... 95 15. MODEL 6495 FREEZING RAIN SENSOR ....... 96 15.1...
  • Page 5: Using This Manual

    This manual details installation and checkout procedures for the All Weather, Inc. Automated Weather Observing System (AWOS) 3000. The AWOS 3000 is available in multiple configura- tions, with each AWOS configuration having a unique suite of sensors. This manual is organized around the individual sensors, with each sensor covered in its own chapter.
  • Page 6: Central Data Processor

    The Central Data Processor (CDP) is mounted in an industrial-grade rack (Figure 1) along with an Uninterruptible Power Source (UPS), VHF ground-to-air radio, voice/RMM (Remote Main- tenance Monitoring)) modem, and any of the CDP options. The available options include UHF data link radio, AWOS Net, and AWOS/ATIS Interface. Figure 1. AWOS 3000 CDP Rack...
  • Page 7: Cdp Installation

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT CDP Installation The CDP is self-contained. It is installed indoors, at a location with access to AC power and any auxiliary communication and data lines required.
  • Page 8 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2. Using a hacksaw, trim the radial length of the antenna (Part M489103) to the length specified. Cover the end of the radiator with the plastic end cap provided with the antenna.
  • Page 9: Cdp Rack Layout

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.1.4 Connecting Optional Printer A parallel port is available on the CDP back panel for connection to a printer. Connect the printer as follows: 1.
  • Page 10 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 5. CDP Top-Shelf Components 2.3.1 Communications The communication options—RS-485 converter or UHF radio—mount to the CDP top shelf in front of the CPU Board/Hard Drive assembly.
  • Page 11 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT The following steps describe how to install the RS-485 converter kit. Figure 6 illustrates the connections.
  • Page 12 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 6. RS-485 Landline Converter Installation...
  • Page 13 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.3.1.2 UHF Radio Installation When a radio data link is used between the DCP and the CDP, a UHF radio is mounted to the top shelf.
  • Page 14 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 7. UHF Radio Installation...
  • Page 15 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Connecting the UHF Antenna When a UHF radio data link is used for communication between the DCP and CDP, the antenna and antenna cable must be installed.
  • Page 16: Cdp Bottom-Shelf Components

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT CDP Bottom-Shelf Components The CDP rack’s bottom shelf (Figure 8) is fixed in place. Components are accessible through the rack’s front or side doors.
  • Page 17 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.4.1.1 AWOS Net CDP Installation The AWOS Net kit includes: • Model 2211 AWOS Net Controller •...
  • Page 18 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 9. AWOS Net Installation 2.4.1.2 Connecting the Local Network to the AWOS Net An Ethernet cable from the LAN must be routed to the CDP and connected to the back panel as follows: 1.
  • Page 19: Gps Ntp Time Standard

    Figure 2). NADIN Interface Connection If a NADIN interface is used with the AWOS 3000, the NADIN serial cable is routed into the CDP and connected to the back panel as follows: 1. Route the NADIN cable to the CDP location.
  • Page 20: Remote Displays Using Awos Net

    D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Remote Displays Using AWOS Net An AWOS Net Controller may be used to receive AWOS data directly from the DCP and output it to a display or local network.
  • Page 21 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 11. AWOS Net 2210 Installation and CDP Connections 2.7.1.1 CDP Connections 1. If a serial cable from an RS-485 converter or UHF radio is connected to the DCP connector on the CDP’s back panel, disconnect it.
  • Page 22 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.7.1.2 AWOS Net Controller Installation 1. Connect the other end of the CAT 5/6 Ethernet cable from the CDP to the RJ-45 adapter on the AWOS Net Controller.
  • Page 23 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 12. AWOS Net 2210-R Installation and CDP Connection 2.7.2.1 CDP Connections Connect the CAT 5/6 Ethernet cable with bare wires in parallel with the DCP-to-CDP RS-485 wires in the terminal box that is also used to connect the DCP to the CDP.
  • Page 24 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.7.2.2 AWOS Net Installation 1. Connect the serial and power cable (pre-installed on the Communication Interface) to the AWOS Net Controller as shown in Figure 13.
  • Page 25 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT These steps explain how to install the UHF Radio Communication Package. Figure 14 illustrates the connections. See also in Chapter 17, Drawings, for additional information about the antenna and mast assembly and installation.
  • Page 26: Kvm Extender For Remote Operation

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT KVM Extender for Remote Operation The KVM Extender Kit (M488342-00) is used to interface a remote operator terminal to the CDP using a CAT6 Ethernet cable between the local and remote KVM Extender units, with the Local Unit connected to the CDP.
  • Page 27 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 6. One power cable — The M491908-00 power cable is used to power the Local Unit from the CDP.
  • Page 28 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 17. Topology of Local and Remote KVM Extender...
  • Page 29 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.8.1 Local Unit Installation The Local Unit of the KVM extender is essentially installed between the computer in the CDP and the keyboard/mouse combination, microphone, and speakers.
  • Page 30 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Remove the two side doors on the CDP and the front door. Remove the four screws holding the front panel to the rack rail in the enclosure (see Figure 5).
  • Page 31 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 20. Local Unit Back Connections Connect the audio extension cable provided in the KVM Extender Kit onto the green speaker connector on the KVM cable.
  • Page 32 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Remove the keyboard USB keyboard connector from the back panel of the CDP (see Figure 2 and Figure 8 for the back panel location and the connector location on the panel).
  • Page 33 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT If the CPU power connector is already being used, use the Y-cable provided with the KVM Extender Kit to provide a power connection to the device on the lower shelf that is already connected.
  • Page 34 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.8.2 Remote Unit Installation The Remote Unit of the KVM extender is installed in the desired operational location for the user.
  • Page 35 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Place the monitor, keyboard, mouse, and microphone in the desired locations. Connect the straight-through CAT6 Ethernet cable from the Local Unit to the REMOTE I/O connector on the back of the Remote Unit (Figure 17).
  • Page 36 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.8.3 KVM Extender Checkout 1. Perform a visual inspection once the Local Unit and Remote Unit connections have been completed to make sure they match the connections shown in Figure 18, Figure 23 (if the Y-cable adapter was used), and Figure 24.
  • Page 37: Awos/Atis Interface

    LED and mode switch on the front of the enclosure, and so does not require the Remote Switch. The Remote Switch may still be used with this model if desired. If the remote switch is used, the 2942 should be installed inside the AWOS 3000 enclosure to prevent access to the mode switch.
  • Page 38 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.9.1 ATIS Peripheral Interface Cable (M491838-00) The ATIS Peripheral Interface Cable is used to connect the AWOS/ATIS Interface assembly to the CDP Peripheral Interface PCB.
  • Page 39 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.9.2 AWOS/ATIS Remote Switch Assembly Mount the Model 2941 Remote Switch used with the Model 2940 AWOS/ATIS Interface at the location where the AWOS/ATIS Interface is controlled from.
  • Page 40 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 28 shows the AWOS/ATIS Interface connections. Figure 28. AWOS/ATIS Interface Connections 1. If a Remote Switch is used, connect its Ethernet patch cord to the BLACK jack.
  • Page 41 D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 3. Connect the WHITE patch cords between the Interface assembly’s WHITE jack and the ATIS’s VHF PTT Keying output, VHF audio output, and Telco audio output. The polarity of these wires is not important.
  • Page 42: Cdp Checkout

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.10 CDP Checkout 1. Check display operation. 2. Check that either the RS-485 converter or UHF radio connections are in place so that the CDP can display data from DCP.
  • Page 43: Cdp Block Diagram

    C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT 2.11 CDP Block Diagram Figure 29 shows a block diagram of the CDP components and their connections.
  • Page 44 C E N T R A L D A T A P R O C E S S O R AWOS 3000 INSTALLATION AND CHECKOUT...
  • Page 45: Data Collection Platform

    D A T A C O L L E C T I O N P L A T F O R M Chapter Data Collection Platform AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS IIIP IIIT IIIPT IIIPTZ  ...
  • Page 46: Auxiliary Sensor Wiring

    C O L L E C T I O N P L A T F O R M AWOS 3000 INSTALLATION AND CHECKOUT Auxiliary Sensor Wiring An auxiliary voltage output sensor (such as a solar radiation sensor) can be connected to the DCP via pins 5 and 6 of TB3.
  • Page 47: Expansion Port

    D A T A C O L L E C T I O N P L A T F O R M AWOS 3000 INSTALLATION AND CHECKOUT 3.6.2 RS-485 Wiring When RS-485 communication is used to communicate with the CDP, pins 7, 9, and 10 of TB4 are used to make the connection.
  • Page 48: Dc, Battery Backup, And Solar Power Wiring

    C O L L E C T I O N P L A T F O R M AWOS 3000 INSTALLATION AND CHECKOUT 3.10 DC, Battery Backup, and Solar Power Wiring TB1 on the DCP backplane provides input power connections for a +15 V DC supply, backup battery power, and solar power.
  • Page 49: Dip Switches

    C O L L E C T I O N P L A T F O R M AWOS 3000 INSTALLATION AND CHECKOUT 3.14 DIP Switches Two DIP switch assemblies (SW1 and SW2) on the DCP backplane are used to set configuration parameters for the DCP.
  • Page 50: Dcp Checkout

    D A T A C O L L E C T I O N P L A T F O R M AWOS 3000 INSTALLATION AND CHECKOUT 3.15 DCP Checkout 1. Verify that all cables are connected and in good condition.
  • Page 51: Model 7190 Dual Digital Barometer

    M O D E L 7 1 9 0 D U A L D I G I T A L B A R O M E T E R Chapter Model 7190 Dual Digital Barometer AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS...
  • Page 52: Checkout

    D U A L D I G I T A L B A R O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 4.1.1 Pressure Connections The barometer is equipped with standard Clippard 11752-1 barbed pressure fittings with 10-32 external thread installed in the barometer.
  • Page 53 D I G I T A L B A R O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT Note the difference in readings for each Model 7190 sensor from the pressure standard reading using in Hg units. If the readings differ by more than 0.05 in Hg, replace the sensor. Otherwise, access the Airport >...
  • Page 54: Model 2020 Micro Response Wind Vane

    Note that it might not be possible to completely comply with the minimum distance requirements from large obstructions when installing the wind vane in an oil rig or rooftop environment. Consult All Weather Inc. for guidance if this appears to be an issue. 5.1.1...
  • Page 55 W I N D V A N E AWOS 3000 INSTALLATION AND CHECKOUT 3. Perform this step indoors where there is no air movement. Holding the sensor in a horizontal position, slide the vane shaft until it balances (the vane does not tip in either direction).
  • Page 56: Checkout

    W I N D V A N E AWOS 3000 INSTALLATION AND CHECKOUT 9. When removing the wind vane for any reason in the future, do not loosen the mounting bolt on the sensor mount or remove the sensor mount from the crossarm. Remove the wind vane from the sensor mount by loosening the mounting bolt on the side of the sensor base.
  • Page 57 W I N D V A N E AWOS 3000 INSTALLATION AND CHECKOUT 2. With the sensor locked in position, stand at the direction benchmark and verify that the tail of the vane is aligned with the vane body. If the vane is not aligned, loosen the mounting screw located at the bottom of the Unistrut, align the sensor (and base) with the benchmark, and tighten the mounting bolt.
  • Page 58 2 0 2 0 W I N D V A N E AWOS 3000 INSTALLATION AND CHECKOUT 4. Verify that the vane’s movement is free and smooth. If it is not, replace the bearings. The shaft should turn freely at all times.
  • Page 59: Model 2030 Anemometer

    Note that it might not be possible to completely comply with the minimum distance requirements from large obstructions when installing the anemometer in an oil rig or rooftop environment. Consult All Weather Inc. for guidance if this appears to be an issue. 6.1.1...
  • Page 60: Checkout

    M O D E L 2 0 3 0 A N E M O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 6.1.2 Mounting The Model 2030 Anemometer must be completely assembled (Section 6.1.1) before it is mounted on the tower.
  • Page 61 2 0 3 0 A N E M O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 2. Connect a Model 1231 run-up motor to the anemometer shaft and power the motor on. The DCP’s LCD display should read between 79 and 81 knots.
  • Page 62: Model 2040 Ultrasonic Wind Sensor

    M O D E L 2 0 4 0 U L T R A S O N I C W I N D S E N S O R Chapter Model 2040 Ultrasonic Wind Sensor AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS...
  • Page 63 W I N D S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT above it that is half blue and half silver (see Figure 34). Align the blue/silver boundary with the red dot, which indicates the North side of the sensor. Mount the sensor to the crossarm while on the ground, before installing the crossarm on the tower.
  • Page 64: Wiring

    U L T R A S O N I C W I N D S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Wiring This section describes the wiring for the three Model 2040 Ultrasonic Wind sensors. Drawing...
  • Page 65 2 0 4 0 U L T R A S O N I C W I N D S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 35. Model 2040 Ultrasonic Wind Sensor Heater Connections Inside DCP...
  • Page 66: Checkout

    U L T R A S O N I C W I N D S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 7.3.3 Model 2040HH Wiring The Model 2040HH signal wires connect to the RS-422/RS-232 converter installed inside the DCP.
  • Page 67: Model 5190 Temperature/Rh Sensor

    M O D E L 5 1 9 0 T E M P E R A T U R E / R H S E N S O R Chapter Model 5190 Temperature/RH Sensor AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS...
  • Page 68: Checkout

    T E M P E R A T U R E / R H S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 12. Route the cable down the tower in the most convenient manner. Lace or strap the cable approximately every 12 inches.
  • Page 69 T E M P E R A T U R E / R H S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT • The reference sensor can take up to ten minutes to stabilize, as the sensor body may have absorbed or lost heat from contact with your body or from storage conditions.
  • Page 70: Model 8190 Motor Aspirated Radiation Shield

    M O D E L 8 1 9 0 M A R S Chapter Model 8190 Motor Aspirated Radiation Shield AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS IIIP IIIT IIIPT IIIPTZ Model 8190 MARS     ...
  • Page 71: Checkout

    M O D E L 8 1 9 0 M A R S AWOS 3000 INSTALLATION AND CHECKOUT Checkout 1. Apply power to the MARS and check to see that the fan is rotating. Check to ensure that all mounting hardware is securely fastened. Verify sensor operation.
  • Page 72: Model 6021 Tipping-Bucket Rain Gauge

    To mount the sensor to a pad, construct the pad using a Ready-Form tube, rebar, and foundation bolts as described in the AWOS 3000 Site Preparation Manual, then proceed as follows: 1. Remove the collection funnel and check the bubble level on the base assembly before bolting the gauge to the foundation.
  • Page 73: Checkout

    B U C K E T R A I N G A U G E AWOS 3000 INSTALLATION AND CHECKOUT 3. Connect the other end of the cable to TB3 at the DCP as follows: a. BLACK and SHIELD wires to TB3, Pin 8 b.
  • Page 74: Model 8364-E Visibility Sensor

    Note that it might not be possible to completely comply with the minimum distance requirements from large obstructions when installing the sensor in an oil rig or rooftop environment. Consult All Weather Inc. for guidance if this appears to be an issue.
  • Page 75: Visibility Sensor Installation

    8 3 6 4 - E V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 11.2 Visibility Sensor Installation Follow the instructions below and refer to Drawings 8364-E-003 and 8364-E-007 in Chapter 17, Drawings to assemble and install the sensor: 1.
  • Page 76: Visibility Control Board Installation

    V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 11.3 Visibility Control Board Installation The visibility control board mounts on the mast below the sensor using the M488173-01 mounting kit.
  • Page 77: Power Connection

    8 3 6 4 - E V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 11.4 Power Connection The following steps explain how to connect AC power to the 8364-E controller board.
  • Page 78: Signal Connections

    8 3 6 4 - E V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Figure 40. Ground Cable Installation 11.6 Signal Connections The Visibility sensor communicates with the DCP via an RS-485 serial connection.
  • Page 79: Additional Kits

    8 3 6 4 - E V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 11.7 Additional Kits The following sections provide installation instructions for the additional kits available for the 8364-E.
  • Page 80: Checkout

    V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 5. The BATTERY START switch is located in the upper left of the control board just to the left of the large, rectangular component U4. To initiate battery power, depress the BATTERY START button and hold it down for 3–4 seconds.
  • Page 81 V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 8. Remove the calibration paddle at this point and insert a piece of black foam over each emitter opening so that no emitted radiation will reach the detectors. Press the # key to continue.
  • Page 82 8 3 6 4 - E V I S I B I L I T Y S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 11.8.2 Battery Backup Checkout Check the Battery Backup operation. 1. Turn the main power switch off.
  • Page 83: Model 8339 Ceilometer

    M O D E L 8 3 3 9 C E I L O M E T E R Chapter Model 8339 Ceilometer AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS IIIP IIIT IIIPT IIIPTZ Model 8339   ...
  • Page 84: Installation

    M O D E L 8 3 3 9 C E I L O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 12.2 Installation The 8339 must be firmly mounted to a vertical 2½" mast for proper operation. Any movement of the 8339 arising from wind or other causes will reduce the accuracy of the ceilometer.
  • Page 85 M O D E L 8 3 3 9 C E I L O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 12.2.1.3 Heater/Blower The Heater/Blower mounts on the mast using the supplied Unistrut and clamps. 1. Mount the Heater/Blower on the mast as shown in installation drawing 83396-00-007 in Chapter 17, Drawings.
  • Page 86 M O D E L 8 3 3 9 C E I L O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 12.2.3 Ceilometer Data Connection 1. Connect the data cable's circular connector to the CEILOMETER DATA connector on the underside of the ceilometer (see Figure 45).
  • Page 87 M O D E L 8 3 3 9 C E I L O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT Figure 46. Desiccant Installation 12.2.3.4 Final Steps 1. Ensure that the circuit breaker on the power supply is in the “ON” position.
  • Page 88: Checkout

    M O D E L 8 3 3 9 C E I L O M E T E R AWOS 3000 INSTALLATION AND CHECKOUT 12.3 Checkout 1. Check blower operation by covering the receiver window with an opaque object (such as a sheet of paper) and verifying that the blower turns on.
  • Page 89: Model 6490 Present Weather Sensor

    Ideally, the area around the site should be free of buildings, trees, and other obstructions. All Weather Inc. recommends that the siting and installation follow the general guidelines established by the Office of the Federal Coordinator for Meteorology (OFCM). The Federal...
  • Page 90: Mechanical Installation

    S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT For AWOS installations, All Weather Inc. recommends that the sensor head be mounted on the sensor tower at a height of ten feet above the tower base. Install the junction box on the tower near the AWOS DCP junction box.
  • Page 91 P R E S E N T W E A T H E R S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT CAUTION Do NOT drill holes in any portion of the sensor head or electronics enclosure! Doing so will void the warranty and may allow water to enter the enclosure! 1.
  • Page 92: Electrical Installation

    W E A T H E R S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 3. Rotate the sensor head until the receive lens is facing north. 4. Tighten the U-bolt nuts when the orientation is correct. (Do not over tighten such that the mounting plate is bent).
  • Page 93 P R E S E N T W E A T H E R S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Table 4. Present Weather Sensor Signal and Power Wiring Sensor Interface Board TB1 DCP TB4...
  • Page 94: Checkout

    P R E S E N T W E A T H E R S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 13.4 Checkout 1. With a clean finger, touch the lenses in front of the disc-shaped heaters which are bonded to the upper and lower inside surface of lenses.
  • Page 95: Model 6500 Thunderstorm/Lightning Sensor

    6 5 0 0 T H U N D E R S T O R M / L I G H T N I N G S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Chapter Model 6500 Thunderstorm/Lightning Sensor...
  • Page 96: Sensor Installation

    Note that it might not be possible to completely comply with the minimum distance requirements from significant RFI sources when installing the sensor in an oil rig or rooftop environment. Consult All Weather Inc. for guidance if this appears to be an issue. 14.3 Sensor Installation The Thunderstorm/Lightning sensor is mounted on a mast that was installed during site preparation.
  • Page 97 T H U N D E R S T O R M / L I G H T N I N G S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 5. Tighten the bolts. 6. Set the sensor package (antenna, ground plane, enclosure, and bracket) on the mast, and fasten loosely with two U-bolts, lock washers, and flat washers as shown in Figure 52.
  • Page 98 T H U N D E R S T O R M / L I G H T N I N G S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 10. The sensor enclosure lid is equipped with hinged bolts (see Figure 54) to allow the box to be opened with the ground plane attached.
  • Page 99: Checkout

    T H U N D E R S T O R M / L I G H T N I N G S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT Table 5. Thunderstorm/Lightning Sensor Signal and Power Wiring...
  • Page 100: Model 6495 Freezing Rain Sensor

    M O D E L 6 4 9 5 F R E E Z I N G R A I N S E N S O R Chapter Model 6495 Freezing Rain Sensor AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS AWOS IIIP...
  • Page 101: Power Connections

    F R E E Z I N G R A I N S E N S O R AWOS 3000 INSTALLATION AND CHECKOUT 3. Install the second U-bolt through the bottom two mounting holes and fasten with flat washers, lock washers, and nuts.
  • Page 102: Foldover Tower Operations

    F O L D O V E R T O W E R O P T I O N S Chapter Foldover Tower Operations 16.1 Lowering the Tower To lower the hinged section of the tower: 1. Remove and retain the four nuts from the bottom two U-bolt clamps. Remove the U-bolt clamps.
  • Page 103: Drawings

    AWOS 3000 CDP Wiring Diagram 3000-A-019 AWOS 3000 2020/2030 Wind Sensor Wiring Diagrams 3000-B-019 AWOS 3000 2040 Ultrasonic Wind Sensor Wiring Diagrams 1190-007 Installation Drawing, 1190 DCP Tower Mounting M403256-01-003 (2 sheets) 2020/2030 Crossarm Assembly Mounting Drawing M403316-003 (Sheet 3)
  • Page 129 This antenna is supplied to operate satisfacto- rily within the frequency range(s) specified on the carton label. Some models require cutting of radiator and/or radials in accor- dance with Figure 11. If the antenna is to be used over a range of frequencies, the element lengths should be chosen for mid-range or favor the element length for the most used, or the frequency requiring the greatest range.
  • Page 130 Lengths on chart are approxi- mate. For finer tuning, use a VSWR bridge if antenna is to be used for transmitting. Remove vinyl cap before measur- ing and cutting. Slide vinyl cap back on after cutting. UHF/VHF Antenna Assembly (cont.) Except as may otherwise be specified by contract, this document and the data disclosed herein and herewith is not to be used,...
  • Page 131 Base and Roof Mount. Vent Pipe Mount. Heavy-gauge steel Brackets attach to 2" to swivel base fits the 5" vent pipes (GC slope of most roofs. 1¼" model fits 2" to 4" vents). mast locks into U-bolt. 1¼" mast clamps into Radio Shack P/N 15-889 place.
  • Page 132 All Weather Inc. 1165 National Drive Sacramento, CA 95818 3000-017 Fax: 916.928.1165 Revision C Phone: 916.928.1000 January, 2011 Toll Free: 800.824.5873...

Table of Contents