Mobile type air conditioner (local air conditioner) (24 pages)
Summary of Contents for Eco Air ECO902SQN
Page 1
R410A SPLIT SERIES FIXED SPEED QUICK COUPLING Models ECO902SQN ead This Manual ECO1202SQN Inside you will find many helpful hints on how to use and maintain your air conditioner properly. ECO1802SQN Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner.
Page 2
BS PLUG WIRING (For models up to 12000 Btu) Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your...
CONTENTS DISPOSAL Disposal............................2 SAFETY PRECAUTIONS Warning ............................3 Caution ............................4 OPERATIING INSTRUCTIONS Parts names ..........................5 Operating temperature........................6 Manual operation ........................6 Airflow direction control ......................7 How the air conditioner works ....................8 CARE AND MAINTENANCE Care and maintenance .........................9 OPERATION TIPS Operation tips ..........................11 TROUBLESHOOTING TIPS Troubleshooting tips ........................13 CAUTION...
DISPOSAL When using this air conditioner in the European countries, the follow information must be followed: DISPOSAL: Do not dispose this product as unsorted waste. It is prohibited to dispose of this appliance in domestic household waste. For disposal, : A) Contact your local council for disposal.
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation may cause harm or damage. The seriousness is classified by the following indications. Failure to follow these instructions exactly, can cause property damage, WARNING death or serious injury.
SAFETY PRECAUTIONS CAUTION When the air filter is to be Do not clean the air Ventilate the room well conditioner with water. when used together removed, do not touch the with a stove, etc. metal parts of the unit. It may cause an injury. An oxygen shortage Water may enter the unit and may occur.
OPERATING INSTRUCTIONS Parts names Indoor unit Indoor unit 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. Vertical air flow louver 7. Display panel 8. Remote controller Outdoor unit 9. Connecting pipe, drain hose Outdoor unit 10.
OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, which is provided separately. Operating temperature Mode Cooling operation Heating operation Drying operation Temperature >17 C Room temperature >10 C <30 C 18 C 43 C • 11 C 4 3 C •...
OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction as appropriate to maximise comfort and even room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(Up--Down) direction Perform this function whilst the unit is in operation using the remote controller.The horizontal louver Range moves at a 6 angle each time the AIR DIRECTION...
OPERATING INSTRUCTIONS How the air conditioner works AUTO operation When you set the air conditioner in AUTO mode, it will SLEEP operation automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature Temperature automatically round the temperature point set by you.
CARE AND MAINTENANCE Care and maintenance Cleaning the Grille, Case and Remote Controller Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Household Drain Cleaner NOTE: Supply power must be disconnectd before cleaning the indoor unit.
Page 12
CARE AND MAINTENANCE 4. Remove the Air Freshening Filter(Optional filter included: Plasma Dust Collector/Silver Ion filter / Bio filter /Vitamin C filter/3M air purifier filter) from its support frame.(The removing and installation method may differ slightly, see the pictures marked on the left.
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
Page 14
OPERATION TIPS 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8.
TROUBLESHOOTING TIPS Troubleshooting Tips Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently.
Page 16
ONE (1)YEAR LIMITED WARRANTY Save This Warranty Information EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages indicated on the unit.
Need help?
Do you have a question about the ECO902SQN and is the answer not in the manual?
Questions and answers