Room Air Conditioners Portable Heat Pump Range ECO10P Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org. For your future convenience, record the model information below. ____________________________________ MODEL NUMBER...
Congratulations! You have purchased the very latest in room air conditioner technology. Your new EcoAir high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your EcoAir air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation.
BS Plug Wiring Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code: BLUE - NEUTRAL BROWN – LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:...
Front Back FIG.5 FIG.6 Control panel Carrying handle Air vent (air outlet) Air inlet Caster Air filter Air inlet Cord hanger Compartment for cord storage Air filter Air inlet Water bung Air outlet Accessories 14. Outward adaptor - for insertion over hose and into foam strip (or into hole in the wall/window).
INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips. Foam strips FIG.8 Offer foam strips to the window gap and cut to size if necessary. Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so that foam is held securely.
Use only the hose provided and FIG.11 clip exhaust hose to the back of the air conditioner. Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down.
INSTALLATION OF CARBON FILTER FIG.15 Remove the filter frame from the unit. Remove the filter fixer from the filter frame. Remove the active carbon filter from its plastic bag. Attach the active carbon filter to the filter frame. Attach the filter fixer to the filter frame (the active carbon filter should be hold between the filter frames and filter fixer firmly).
OPERATION OF CONTROL PANEL Control panel FIG.16 Mode (function) option button 10. Heating mode operation indicator ( only available for the mode with heating function, Timer button please refer to the actual unit you purchased) 'Temperature up' button 11. Timer operation indicator 'Temperature down' button 12.
Page 12
Setting mode/function Press MODE button to select required working mode: automatic, cooling or fan. The indicator of your selected mode comes on. Setting temperature Press 'Temperature up' or 'Temperature down' button to regulate the temperature you desired. The display window will show the temperature you set as you press 'Temperature up' or 'Temperature down' button.
Page 13
Regulating air flow direction FIG.19 The up & down air flow direction can be adjusted by moving the air vent directly. FIG.18 Turn the roller on the air vent to control the air flow direction left or right. NOTICE ! To prolong the compressor's life, after switching off the unit, please wait for a minimum of 3 minutes before switching on again.
DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require water drainage when tank is full.
Page 15
The drain tube may be extended by adding an extension tube and using a suitable connector. Water hole Supplied drain tube FIG.22 Extension tube (OD: 18 mm) Please note The drain must be at or below the outlet level. 2. ‘Water Full’ indicator will not function in this mode of drainage. 3.
MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.
FAULT CHECK LIST The air conditioner does not run Is the air conditioner plugged in? Is there a power failure? Is the comp / ‘full water’ indicator flashing? Is the room temperature below the set temperature? The machine seems to do little Is there direct sunshine? (Please put down the curtain.) Are too many windows or doors open?
EASY TO ORDER FORM FOR ACCESSORIES (Please complete in BLOCK CAPITALS in black ink) Full Name: Previous Invoice No.: (If available) Model No. Delivery Address: Telephone No.: Email Address: Signature UNIT DESCRIPTION PRODUCT CODE TOTAL PRICE Filters Left Filter for Condenser 10P-114 £12.99 Rear Filter for Condenser...
Page 19
ONE (1) YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must be operated under conditions as recommended, at voltages indicated on the unit.