7. HARDWARE SPECIFICAT IONS 
Power supply 
● 
Working enviroment 
LCD 
Buttons 
Real time clock 
RAM 
Power backup system 
Communication system 
Output contr ol system 
(A) Alarm ou tput termina l can b e con nected with a dditio nal external alarm unit for 
so unding. 
(B) O pen do or output ter minal can be matching used with elec tric lock for a ccess 
co ntrol. 
(C) A nti­duress ou tput te rminal can b e connected with hidden alarm to sen d help 
signal to the nearest police statio n. 
Input sensin system 
● 
(A) P ush bu tton door op en sensing p oint.D oor will open instan tly when button is 
pressed . 
(B) D oor sta tus te rminal can be conn ected with externa l magn etic sp ring for sensing 
if the do or is closed or not. 
(C) A nti­the ft sensing terminal can be conn ected with externa l magn etic sp ring for 
se nsing if any applia nces a re closed or not. 
(D) A nti­tamper sensing termin al use d to se nse if the re ader is being tampe red b y 
fo rce. 
8. ATTENTIONS 
1. Confirm the power supply volta ge and polarly befo re ins tallatio n to prevent any 
wrong conne ction that ca useda mage to the reader. 
2. Use separate pow er sup ply to the electric lo ck and the p roximity read er. 
3. Do no t insta ll the r eader nearly any metal eq uimen ts or d etecto r area to pre vent 
interfe rence of rea d dista nce. 
4. Do no t try to fix or modify the re ader without autho rized e lectrician.The reader is 
guara nteed for one year. 
9. T ROUBLESH OOTING 
1. Reader has no rea ction o r door does not open with proximity card. 
Solutio n: (1) Please check if the POW ER ligh t(red)is on.If not,p lease check the po wer 
supply to run the reader o n. 
(2) Pleas e check if the proximity ca rd is d efected.Use r may use an other proximity 
card to test. 
(3) Pleas e check if pe rsonal password is entere d incorrectly or the user is still in 
the setup mo de. 
(4) Continuous proximity.Ple ase re move the ca rd from the reader and try again. 
(5) Check if the DENY light(y ellow ) is on and continuo us beep sou nd occur. Th is 
indica tes the user' s proximity card is not reg istered yet. 
(6) Pleas e check if OK Light(green) is on and d oor­op ening sound can b e heard 
at the s ame time.If door is still not opened,p lease ensure that if the wiring or 
:DC 12V/1A,Adapter. 
Temperatur e 0 C­6 
16*2 STN LCD display with 4 LED's indicators. 
12 stainless steel buttons. 
Internal equ ipped with a Real Time Clock(RTC)IC. 
128 KB mem ory. 
Equip ped with standby battery for saving if power is cut. 
Equip ped intermally with RS­485 interface.It can be 
 
expanded to 255 terminals linking with computer operation 
 
simultaneously. 
24
。 
0 C,Humidity
15%­85 %. 