  • Page 1 CCTV XD200 Model: High Capacity RF/PIN Access Control System XD200 Model: High Capacity RF/PIN Access Control System Manufactured exclusively for Xvision www.x-vision.co.uk...
  • Page 2: Table Of Contents

    CONTENTS  1. Features Intro ductions  3  2. R eader Front panel & types of proximity card  4  3. O peration inst ructions  5  Start reader  5  Mode inquiry  5  Anti­duress  5  Setup mode  5  4. Q uick setting  6  5. S etup mode function selection instructions (00~28)  6 ...
  • Page 3: Features Introductions

    Operating Instructions ST­680 OPERATION INSTRUCTIONS  1. Features introductions  W hen connecting with computer,it can b e used for d ata inquiry and function s etting  simutaneously.(Doo r open/close,start a larm system,etc).It can also op erate solely to  manage access control.  Fu nction setting can be do ne by computer or reader itself.(Single registration or ...
  • Page 4: R Eader Front Panel & Types Of Proximity Card

    A nti­du ress  ­ It will operate when password and duress code are keyes in to send help  * signal to the nearest police station.It must b e done manually to disable  anti­duress function.  Exceed door shut time ­ Alarm will be activate d,whe n door is not closed exceeding intial  *...
  • Page 5: O Peration Inst Ructions

    RTC TESTING  Real time clock teseing  INITIAL FUNCTION  Initial system setting  <<XD200>> 08:05 Model (XD200), Time (08:05), 10 registrations <<ST680>> 08:05  Model (ST680),present time (08:05),10 registrations.  0010 0010  Note: Card must not exceed the read range (refer to different m odels) to ...
  • Page 6 4. Q uick setup:  User will get into the setup mode as the right diagram shown for any settin g  to be made.  0 1 0 0 0 0 0 0 0 1 (A) Add new card , key in then key in . ...
  • Page 7 Function (02) D elete card:  Deletion of user's card (such as loss of card or to prevent specific user to gain  access) can be achieved by keying 8­digit card number indicated on the  proximity card.  E sc sys tem fu nction selec tion.  Key in # or * ...
  • Page 8 Function (05) D oor open mode:  R eader has 2 types of identification modes. (pre­setting figure is 002)  M ode (2).  Card proximity door opening : The door w ill be opened , when the c ard  is sensed.  M ode (3).  Door open by proximity card and password: The door will be opened ...
  • Page 9 Function (08) C hange system password:  The reader's password is being set at 5 67 8 initially by manufacturer.  In order to enter into system setting mode for the first time, user must  key in the initial system password 5 6 7 8  .
  • Page 10 Function (10) R eader ID num ber:  Each reader has a reader ID number for computer identification and the number  should not be repeated. (pre­setting figure is 001)  Esc system function s electi on.  Key in # or *  sta tus ligh t on,d isplay  Q ueuing the id entific ation ...
  • Page 11 Function (12) Anti­duress co de :  * 0 ~ 9 *  Set up of anti­duress code ( , ). (pre­setting code is )  E sc sys tem fu nction selec tion.  Key in # or *  sta tus lig ht on,display  Q ueuing for anti­du ress ...
  • Page 12 Function (15) Set time:  Example: 18 hour 00 minute 00 second => 18:00:00 (pre­setting figure is  00:00:00)  E sc sys tem fu nction selection.  Key in # or *  sta tus lig ht on,d isplay  Q ueuing for system  Go into sy stem f unctio n setu p.  fun ction s electi on. ...
  • Page 13 Function (17) Auto Record range:  This is to set under what kind of status to save by stand alone operation.  (pre­setting figure is 003). There are 4 kinds of sta tus to choose:  A. Detect point / output action. (+1) B. Computer special command. (+2) ...
  • Page 14 Function (19) D oor shutting time:  Time setting for sensing door­shutting time as to activate the alarm when  exceeding the set value. (pre­setting value is 030)  E sc sys tem fu nction selection.  Key in # or *  sta tus lig ht on,d isplay  Q ueuing for do or ...
  • Page 15 Function (21) Anti­duress alarm mode:  (0) shows "ON" ,(1) shows "OFF", (pre­setting figure is 000). Once set at  "OFF", anti­duress alarm will not function.  E sc sys tem fu nction selection.  Key in # or *  sta tus lig ht on,d isplay  Q ueuing for an ti­ ...
  • Page 16 Function (23) Anti­theft sensing mode:  (0) shows "ON", (1) shows "OFF". (pre­setting figure is 000). Once set at  "OFF", the sensing mode will not function at any cases of broken in.  E sc sys tem fu nction selection.  Key in # or *  sta tus lig ht on,d isplay ...
  • Page 17 Function (25) BEEP sound m ode:  (0) shows "ON", (1) shows "OFF". (pre­setting figure is 000). Once set at "OFF"  , the BEEP sound will not function.  E sc sys tem fu nction selection.  Key in # or *  sta tus lig ht on,d isplay  Q ueuing for B EEP ...
  • Page 18 Function (27) Anti­pass mode:  (0) shows "O N", (1) show s "OFF". (pre­setting figure is 001) Once set at "ON "  , the card could only be used for matching single entry and exit. This is to  prevent double entry by using the sam e card if card has been duplicated.  E sc sys tem fu nction selection. ...
  • Page 19 Function (00) Instant door open:  Authorized personnel could get into the setup mode to open the door when any  emergency cases happened.  Esc system func tion se lectio n.  Key in # or *  status light on,display  Que uing f or doo r  Go int o system fun ction s etup. ...
  • Page 20: Installation Instructions

    6. Reader installation instructions  (1)Reader connector  XD200 Wiring Diagram ST680 Wiring diagram  5 PIN CONNECTOR  Ye llow  G ND  Pu rple  PWM  Pu rple  A nti­du ress o utput termin al (low active )  Blu e  Sub Reader connecto r 1. ...
  • Page 21: Wiring Connection For Additional Magnetic Door Sensin G

    (b) Fail safe :  8 PIN CONNECTOR  6 PIN CONNEC TOR  R BK BR O Y G BL P R BR G BL P Y  Jump Adjustme nt  (JP10)  Push butt on switch  -  Di ode s white c olor termina l  N.C Outp ut ...
  • Page 22: Wiring Connection For Additional Alarm

    (5) Wiring connection for additional alarm.  (a) Alarm :  8 PIN CONNECTOR  Jump Adjus tment  R BK BR O Y G BL P  (JP10 )  N.O Output  N.C Output  Diode s white  c olor terminal  +  Alarm power  -  s upply DC12V  N ote User must ensure the polarity (Diode) of th e wiring connection for ...
  • Page 23: Wiring Connection For Linking With Computer

    (6) Wiring connection for linking with com puter  RS­485  8 PIN C ONNECTO R  8 PIN C ONNECTO R  8 PIN CONNECTO R  R BK BR O Y G BL P  R BK BR O Y G BL P  R BK BR O Y G BL P  RS­485 inte rface transit connect or ...
  • Page 24: Hardware Spec Ifications

    7. HARDWARE SPECIFICAT IONS  :DC 12V/1A,Adapter.  Power supply  ●  。 。  Working enviroment  : : Temperatur e 0 C­6  0 C,Humidity 15%­85 %.  ● : 16*2 STN LCD display with 4 LED's indicators.  LCD  ● : Buttons  12 stainless steel buttons.  ●...
  • Page 25 powe r supp ly of e lectric lock is installed pro perly or bro ken.  2. Syste m password is ente red bu t user canno t enter into v arious function selection of  the setting mode.  Solutio n: (1) System password is ente red inc orrectly.Ple ase ch eck if the follwing s tep ha s  been e ntered correctly.
  • Page 26 APPENDIX A  In stallation Steps :  Step 1,2Secure pow er sup ply wire and control wire through the base panel.  Step 3 Fit the rea der on the base panel (power supply wire and control wir e  mus t first be inserted a nd the wires must be arranged correctly)  Step 4 Use enclo sed ke y wrench and screws to mount the reader up.
  • Page 27: Wiring Diagram

    Wiring Diagram Wiring diagram of ST­680 and ST­110ERB/ST­120ERB  Reader  XD200 ST­110ERB/ST­120ERB  ST­680  R BK BR O Y GR BL P  8Pin  AP­10  DC 12V  AP­10  DC 12V  R BR G R BL P  ST­680 5Pin  XD200 S  S  G  P ...
  • Page 28: Technical Support

    TECHNICAL SUPPORT: For Technical Support for any Xvision product please contact your local distributor. LIMITED WARRANTY: This product is supplied with a 1 Year warranty. The Warranty excludes products that have been misused, (including accidental damage) and damage caused by normal wear and tear. In the unlikely event that you encounter a problem with this product, it should be returned to the place of purchase.

Table of Contents