3 1/2 DIGITS DIGITAL MULTIMETER
600.005
Gebruiksaanwijzing
Mode d'Emploi
Gebrauchsanleitung
Brugsanvisning
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for SKYTRONIC 600.005

  • Page 1 3 1/2 DIGITS DIGITAL MULTIMETER 600.005 Gebruiksaanwijzing Mode d’Emploi Gebrauchsanleitung Brugsanvisning Instruction Manual...
  • Page 2: Safety Information

    The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the warnings contained in this manual. SkyTronic UK cannot be held responsible for personal injuries caused by a disrespect of the safety recommendations and warnings. This is also applicable to...
  • Page 3 WARNING To avoid possible electric shock or personal injury, follow these guidelines: • Do not use the meter if it is damaged. Before you use the meter, inspect the case. Pay particular attention to the insulation surrounding the connectors. • Inspect the test leads for damaged insulation or exposed metal.
  • Page 4: Maintenance

    CAUTION To avoid possible damage to the meter or to the equipment under test, follow these guidelines: • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. • Use the proper terminals, function, and range for your measurements.
  • Page 5 DC VOLTAGE Range Accuracy Resolution 200mV 100•V ±(0.8%+1) 10mV 200V 100mV 500V ±(1%+1) Input impedance: 1MΩ for all ranges. AC VOLTAGE Range Accuracy Resolution 200V 100mV ±(1.5%+10) 500V Input impedance: 452KΩ Frequency range: 50Hz~200Hz DC CURRENT Range Accuracy Resolution 1µA ±(2%+2) 20mA 10µA...
  • Page 6: Diode And Audible Continuity Test

    DIODE AND AUDIBLE CONTINUITY TEST Range Description Test Condition The approx. forward The forward DC current voltage drop of the diode is approx. 1mA, the will be displayed on the reversed DC voltage is LCD. approx. 2.8V. If the resistance of the circuit under test is less Open circuit voltage is than 40Ω, the built-in...
  • Page 7: Dc Current Measurement

    DC CURRENT MEASUREMENT Connect the red test lead to the “mA” jack and the black test lead to the “COM” jack. Set the range switch to the desired “ ” range. If the current to be measured is not known beforehand, set the range switch to the range and then turn down range by range until satisfactory resolution is obtained.
  • Page 8: Audible Continuity Test

    AUDIBLE CONTINUITY TEST Connect the red test lead to the “VΩ” jack and the black test lead to the “COM” jack. Set the range switch to the “ ” range. Connect the test leads to the two terminals of the circuit to be tested.