Page 1
Co nt r ol Un i t User’s Manual Model 550550 This User’s Manual is also available online in English, French, German, Italian, Japanese, and Spanish at www.gameready.com under Products.
A B l e o F C o n t e n t S Description of Device _______________________________________ 2 Introduction to Game Ready _________________________________ 3 Detailed Instructions for Use _________________________________ 4 Using Your Game Ready System _____________________________ 7 Indications for Use __________________________________________ 11 Contraindications ___________________________________________ 11 General Warnings and Cautions _____________________________ 11...
Wrap Sleeve Game ready System: The following items are included in your Game Ready System: a Control Unit, an AC Adapter, a Power Cord, a Connector Hose, and a Welcome Packet, containing the User’s Manual and other information about the System. Each Wrap...
Warranty Section of this manual. don’t JUSt treAt SYSteMS, Help ACCelerAte HeAlinG To learn more or to share your experience with the Game Ready System, please call us at 1.888.426.3732 or email us at info@gameready.com. We’d enjoy hearing from you.
d e t A i l e d i n S t r U C t i o n S F o r U S e ModeS oF operAtion Manual Mode: The System defaults to this mode, and allows the user to adjust time and pressure settings.
Page 6
d e t A i l e d i n S t r U C t i o n S F o r U S e Adjusting Temperature temperature: Knob More Cold Less Cold Full Cold Turn knob counter-clockwise Turn knob clockwise for for less cold therapy more cold therapy diSplAY...
Page 7
d e t A i l e d i n S t r U C t i o n S F o r U S e When the System Sleep time Displays the amount of run time is running in count-down bars remaining program Mode:...
The Wrap is comprised of an inner Heat Exchanger and an outer Sleeve. The combination • of Sleeve and Heat Exchanger is referred to throughout this manual as a “Wrap.” The Game Ready Control Unit should be placed on a stable surface (such as the floor or a • table) during use.
Page 9
If the light is still not illuminated and the Control Unit will not turn on, please contact Game Ready Customer Service; from the U.S. call Toll-free at 1.888.426.3732, from outside of the U.S.
Page 10
Click Disconnect Button If you have any problems with the set-up of your Game Ready System, please contact Game Ready Customer Service; from the U.S. call Toll-free at 1.888.426.3732, from outside of the U.S. call +1.510.868.2100. Warnings: Follow the recommendations of your health care practitioner.
Page 11
U S i n G Y o U r G A M e r e A d Y S Y S t e M Press the power button. The screen should light up and theControl Step 9: Unit should beep once. The power indicator light should turn from orange to green.
(e.g., carcinoma). Who have decompensated hypertonia in the affected region. • Cryotherapy using the Game Ready System or any cryotherapy device should not be used in patients: Who have significant vascular impairment in the affected region (e.g., from prior frostbite, •...
Page 13
To avoid the risk of electrical shock, do not remove any panels from the Control Unit. • Opening the case will void the Game Ready warranty. For all servicing and repair, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S.
U l C l A S S i F i C A t i o n protection against electric shock: The Game Ready System is considered to be Class I (protective earth) when connected to the Ault Model MW 128 power supply, and Class II (double insulated) when connected to the GlobTek Model GTM-21097-5012 power supply.
C l e A n i n G Control Unit The exterior of the Control Unit and the visible interior surfaces of the reservoir can be cleaned with a soft cloth and one of the following cleaning agents: Mild detergent •...
Be sure to test any product on a small portion of the Bag to ensure that it will not cause damage. note: To operate the Game Ready System, you do not need to remove it from the Carry Bag. Simply unzip the Bag’s main compartment and end panel. Fill the reservoir with ice and water.
DC input: 12V/2.5 A A C C e S S o r i e S The Game Ready Control Unit can be used with any of the following accessories: Any Game Ready Wrap. Wraps made by any other manufacturer CANNOT be used with •...
t r o U B l e S H o o t i n G WHAt doeS WHAt CAn error it MeAn? i do? Air pressure Sensor: The • This is most likely to occur if you Control Unit has detected have restarted the System with an a problem calibrating the inflated Wrap attached.
Page 19
LED on the control panel is illuminated, but the Control Unit will not turn on, call 1.888.426.3732. If no orange or green light is illuminated, check that the electrical outlet has power. note: If any problem persists call Game Ready Customer Service at 1.888.426.3732. EN-18...
You must use the original packaging or the equivalent. CoolSystems may require you to verify in writing that you are the original purchaser of the Game Ready Control Unit. CoolSystems may elect to replace or repair the Game Ready Control Unit with either a new or reconditioned product.
7 days of purchase. reGiStrAtion Please complete the Warranty Registration within 30 days for both the Game Ready Control Unit and the Wraps online at www.gameready.com. You will need the following information to complete your Warranty Registration: the Control Unit’s model number...
Need help?
Do you have a question about the 550550 and is the answer not in the manual?
Questions and answers