A B l E C o N t E N t S Safety Precautions _________________________________________ 4 the Game ready Equine System Control Panel/ Basic Controls ___________________________________ 7 Priming A New Wrap _________________________________________ 7 Control Unit Setup ___________________________________________ 8 Applying the Wraps __________________________________________ 9...
Caution: this product is for veterinary use only and is not indicated for human use. Caution: do not use any AC adapter other than that provided by Game ready Equine. Use of other AC adapters may result in electrical shock and will void Game ready Equine warranty.
Page 7
C l A S S I F I C A t I o N Protection against electric shock (5.1): the Game ready power supply (Ault Model MW128) is considered to be Class I (grounded) equipment. the Game ready power supply (Globtek Model GtM21097-5012) is considered to be Class II (ungrounded) equipment.
Page 8
Y o U r G A M E r E A d Y E Q U I N E S Y S t E M Control Unit Heat Exchanger Sleeve Carry Bag (optional) Connector Hose AC Adapter User's Manual C o N t r o l U N I t o r I E N t A t I o N S Figure A: Upright...
C o N t r o l P A N E l / B A S I C C o N t r o l S Power (on/off) Pressure display Green indicates unit has power Second tick marks Celsius/Fahrenheit Timer on Alarm silencer Pressure setting Start/pause...
C o N t r o l U N I t S E t U P Filling the Ice Box Stand unit upright. then unplug the unit from the electrical outlet. to open the ice box lid, pull up on the latch on the end panel of the Control Unit.
If skin has been breached, first apply a sterile dressing over the wound, then apply the Game ready Equine Wrap. After treatment, remove the Wrap from the horse and disconnect from the Control Unit.
Air Pressure: When operating on low, medium or high pressure, the Game ready Control Unit is designed to alert the user if it does not achieve its minimum or maximum pressure requirements. It’s possible for the horse to make the Control Unit “think”...
G E t t I N G S t A r t E d 1. Pull up latch to release and open ice box lid. 2. Fill reservoir to the rim with ice. 3. Pour cold water over ice until the reservoir is about one third full. 4.
C o N t r o l P A N E l Power (on/off) Pressure display Green indicates unit has power Second tick marks Celsius/Fahrenheit Timer on Alarm silencer Pressure setting Start/pause Increase time Decrease time Timer setting P r E S S U r E S E t t I N G S Pressure Settings No pressure...
Page 15
Adjusting Pressure Press the pressure button on the control panel to adjust the level of compression. the system has four pressure options: 1. No pressure: circulates the ice water only 2. low pressure: inflates and deflates the Wrap from 5-15 mm Hg over approximately 5 minute cycle. 3.
B A G to operate the Game ready Equine System, you don’t need to remove it from the bag. Simply unzip the bag’s main compartment and end panel. to fill with ice and water, open the ice box lid. Connect the Wrap hose and the AC adapter to the end panel of the Control Unit.
1° - 50° C (33° - 122° F) relative Humidity: 10% - 95% non-condensing Store the Game ready Equine System in the carrying bag or on a shelf, preferably with the lid open to allow the interior to dry.
Wipe clean with mild soap and water, air dry. Caution: Store the Game ready Equine System out of the reach of children and pets. H o W t o P A C K t H E G A M E r E A d Y E Q U I N E S Y S t E M AC Adapter User’s Manual...
Mains power quality should be that of a typical commercial or hospital environment. Surge protection is recommended to protect Control Unit. If the user of the Game ready Equine System requires continued operation during power mains interruptions, it is recommended that the Game ready Equine System be powered from an uninterruptible power supply.
Wrap or not, call compression circuit, either in the Game ready Equine customer service at connector hose or the Wrap itself. 888.GAMErEAdY (426-3732) You can this is a Soft Error. there is no...
Page 21
t r o U B l E S H o o t I N G Error WHAt doES It MEAN WHAt CAN I do? Pressure Sensor Alarm • Disconnect the Wrap from the Control Unit. the Control Unit has detected a •...
Page 22
Wrap again. If the Control Unit shuts off again, there is either a problem with the Wrap or the Control Unit. try a different Wrap to determine if it is the Control Unit or the Wrap and call Game ready customer service at 1-888-GAMErEAdY for further assistance.
CoolSystems warrants that the Game ready Control Unit, if properly used, will be free from defects in material and workmanship for a period of one (1) year after the date the Game ready Control Unit was purchased. If the Game ready...
HoW to CoNtACt US Game ready Equine Customer Service department 1201 Marina Village Pkwy Suite 200 Alameda, CA 94501 510-559-3940 toll-free phone number: 1-888-GAMErEAdY (1-888-426-3732) www.gamereadyequine.com Game ready Equine Control Unit Users Manual 701317 rev F...
Need help?
Do you have a question about the Equine 550250 and is the answer not in the manual?