Refrigerant Piping - Daikin FVXS25FV1B Installation Manual

R410a split series
Hide thumbs Also See for FVXS25FV1B:
Table of Contents

Advertisement

Indoor Unit Installation (1)
Exposed installation
1.

Refrigerant piping

1) Drill a hole (65mm in diameter) in the spot indicated by the
2) The location of the hole is different depending on which side of the pipe is taken out.
3) For piping, see 6. Connecting the refrigerant pipe, under Indoor Unit Installation (1).
4) Allow space around the pipe for a easier indoor unit pipe connection.
Left back piping
CAUTION
Min. allowable length
• The suggested shortest pipe length is 2.5m, in order to avoid noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
• See the installation manual for the outdoor unit for the maximum pipe length.
• For multi-connections, see the installation manual for the multi-outdoor unit.
Refrigerant pipe
2.
Boring a wall hole and installing wall embedded pipe
• For walls containing metal frame or metal board, be sure to use a
wall embedded pipe and wall cover in the feed-through hole to
prevent possible heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material
to prevent water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down
slope toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping,
caulk pipe hole gap with putty.
5
Left bottom piping
75
75
Right back piping
Wall
symbol in the illustration as below.
Wall
Right bottom piping
75
75
Left/right piping
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
(Unit : mm)
45
75
Floor
Inside
Outside
Caulking
Wall embedded pipe
(Field supply)
■English